Program Section: M001 (Modules)

M0xx

È00 Keypad Selections

NOTE: “xx” represents the module number: 01 – 24.

(left to right on keypad screen) N America Example:

Pressing the keypad button under È

?

will display the type of module and the module’s input and output ranges.

Name

Selections

Description

Regional Settings Default

Serial Number

00000 - 65535

5 digit # on sticker on module circuit board.

00000

Area

01 – 16

Module assigned to which area?
2 Digits 01 – 16 = Area #

01

Inputs

0 = 0, 1 = 4, 2 =
8, 3 = 12, 4 = 16,
5 = 20, 6 = 24, 7
= 32

The number of input points (sensors) supported
by the module.
Default for Area 1: 4, Default for Area 2: 1

2

Outputs

0 = 00, 1 = 04, 2
= 08, 3 = 12, 4 =
16, 5 = 20, 6 =
24, 7 = 32

The number of programmable outputs sup-
ported by the module.
Default for Area 1: 1, Default for Area 2: 1

1

Exit Delay

0 = Never.
1 = When arming
to Stay or On
*2 = Not used
3 = When arming
to On

If the keypad has the Exit delay set to 1, this
means that the keypad would be protected
when the area goes into Stay 1, 2 or On. An
exit delay occurs and, if Alarm on Fail to Exit is
set in the area configuration, the system must
see a door transition otherwise a Fail to Exit will
result. Of course this would be an internal door
whose level is set to 1 or 2 or 3.
If the keypad is outside the protected area, the
Exit delay is set to 0. When arming the area,
the UI would not be affected.

1

Entry/Exit Tones in
Stay

9

(yes)

(no)

Are E/E tones to sound at this (keypad) if a
door opened with area armed to 'Stay'.

9

(yes)

Monitor Tamper

9

(yes)

(no)

NOTE:

9

(yes) if module requires tamper,

comms, substitution detection

9

(yes)

(

Definitions): Stay:

Perimeter sensors monitored (plus any 24 hr sensors); On: All sensors monitored.

Keypad NOTES

If the keypad module has the Exit delay set to 1, this means that the keypad would be protected when the area goes into Stay
or On. An exit delay occurs and, if Alarm on Fail to Exit is enabled in the Area Program Section: A0xxÈ01, the system must
see a door transition otherwise a Fail to Exit Alarm will result. This would be an Entry/Exit door whose protection level is set to
Stay

or On.

If the keypad module is outside the protected area, the Exit delay is set to 0. When arming the area, Alarm on Fail to Exit would
not apply.

00000

·

01

·

2

·

1

·

1

·

9

9

È

Save

È

?M001

И