Input points – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 16

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

12

Input Points

Point Types: EE(entry/exit)Door, EE Route, Perimeter, Motion, Fap Motion, Day Warning, Burglary, Fire Class A, Fire
15s (second), Fire 0s (immediate), Hold-up, Aux Alert (auxiliary alert/emergency), Supervisory, Local 24h (hour), Lcl
StayOn (Local Stay-On), Lcl Stay20n, Local On Only, undefined.

FAP:

(False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and

immediately resets, a 20 minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.

Circuit Types: NC (normally closed), NC SERIES2K (normally closed with 2.2K End of Line resistor), NO PARALL2K
(normally open with 2.2K End of Line resistor), DUAL 2K2 EO (Form “C” Dual 2.2K End of Line resistor)
Circuit Types UK: NO, 2K-ALM 1K-O, Type2 2K2EO, Type2 8K2EO.

Point
Location

Regional
Setting

Default Point
Type

Default Name

Default Circuit Type

Assigned to Default
AREA

N America

Entry/Exit Door

FRONT DOOR

NO PARALL2K

A01: OFFICE

European Entry/Exit

Door FRONT DOOR

TYPE2 2K2EO

A01: AREA DE(SCRIP)

U.K. ACPO

Custom # 80
(Command Point,
Class:
Supervisory.

See Custom Point
Programming and
ACPO in Advanced
Programming )

LCLCMDATEALL

NO

A01: AREA DE(SCRIP)

Aus/NZ Entry/Exit

Door

FRONT DOOR

DUAL 2K2 EO

A01: OFFICE

China/H.K. Entry/Exit

Door FRONT DOOR

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Netherlands Entry/Exit

Door

FRONT DOOR

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Switzerland Entry/Exit

Door FRONT DOOR

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Point 001

,

main
control
board.

France Entry/Exit

Door

FRONT DOOR

TYPE2 2K2EO

A01: AREA DE(SCRIP)

N America

Entry/Exit Route
(set to ON)

LOBBY MOTION

NO PARALL2K

A01: OFFICE

European EE

Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

U.K. ACPO

EE Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Aus/NZ Entry/Exit

Route

(set to ON)

LOBBY MOTION

DUAL 2K2 EO

A01: OFFICE

China/H.K. EE

Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Netherlands EE

Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Switzerland EE

Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Point 002

,

main
control
board.

France EE

Door

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

N America

Motion
(set to ON)

OFFICE MOTION

NO PARALL2K

A01: OFFICE

European EE

Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

U.K. ACPO

EE Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Aus/NZ Motion

(set to ON)

OFFICE MOTION

DUAL 2K2 EO

A01: OFFICE

China/H.K. EE

Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Netherlands EE

Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Switzerland EE

Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Point 003

,

main
control
board.

France EE

Route

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

N America

Motion
(set to ON)

INTR MOTION
(interior motion)

NO PARALL2K

A01: OFFICE

European Motion

(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

U.K. ACPO

Motion
(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Aus/NZ Motion

(set to ON)

INTR MOTION
(interior motion)

DUAL 2K2 EO

A01: OFFICE

China/H.K. Motion

(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Netherlands Motion

(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Switzerland Motion

(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Point 004

,

main
control
board.

France Motion

(set to ON)

CCT DESCRIP

TYPE2 2K2EO

A01: AREA DE(SCRIP)

Point 005

,

N America

Motion
(set to ON)

REAR MOTION

NO PARALL2K

A01: OFFICE

Advertising