Outputs (uk version) – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 26

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

22

Outputs (UK version)

Select Output

Select Group
(Program Section)

Select Condition

Select Operation

B001 – B128

System

Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm, ACPO Fire, ACPO Attack, ACPO
Unconfirmed, ACPO Set, ACPO F/Faul (Fire
Fault), ACPO Bypass, ACPO Confirmed, ACPO
Siren, ACPO Strobe.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Areas
Select Area #

ACPO Fire, ACPO Attack, ACPO Unconfirmed,
ACPO Set, ACPO F/Faul (Fire Fault), ACPO
Bypass, ACPO Confirmed, ACPO Siren, ACPO
Strobe.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Protection Points
Select Point #

Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Outputs
Select Output #

Real OP (output) On, Equation is True, Manual
Command.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Modules
Select Module #

On Line, Tamper, Comms Trbl, (Communications
Trouble), Battery Trouble, User Loged On.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Equipment Points
Select Point #

System Tmpr (Tamper), Low/No Battery, AC Mains
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.

Toggle, Normal, Time
Delay or Inverted

UK Default Outputs

Select Output

Select Group
(Program
Section)

Select Area,
Point, etc.

Select Condition

Select Operation

B001 Relay 1
motherboard

System

000.66 ACPO Siren

Inverted

B002 Relay 2
motherboard

System

000.67

Confirmed

Alarm (ACPO strobe)

Inverted

B003 WW STU

Areas

Area 1

001.33 When area Entry / Exit delay is in
progress – provides a steady output
(STAY & ON).

Normal

B004 WW STU

System

000.60 Personal ACPO Attack

Normal

B005 WW STU

System

000.61 ACPO Unconfirmed Alarm

Inverted

B006 WW STU

System

000.62 ACPO Area Set / Unset

Inverted

B007 WW STU

System

000.64 ACPO Bypass in Effect

Inverted

B008 WW STU

System

000.54 Local AC (mains) failure.

Inverted

B009 WW STU

System

000.65 ACPO Confirmed Alarm

Inverted

B010 WW STU

Areas

Area 1

001.32 Area is in ‘Walk’ or ‘Hold-up’ test. Inverted

B011 – B128

Undefined

WW STU = World Wide modem with outputs