xL Regional Settings Guide

21-3609E rev1.0

42

S004

È04 Secondary Card Format—Odd-Parity Checking

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Odd Parity
Position

1 – 40

The position of the odd-parity
'checksum'.

26

(U.K. ACPO = 00)

Odd Parity Start

1 – 40

This is the position of the first data-bit to
be included for odd-parity checking.

14

(U.K. ACPO = 00)

Odd Parity
Length

0 – 40

If either the odd parity length = 0 or even
parity length = 0, then parity will not be
checked.

12

(U.K. ACPO = 00)

Odd/Even Parity checking:

This feature (which applies only to Wiegand-format cards) helps prevent card misreads.

To disable parity checking:

Set the 'Parity Length' to 0 (zero).


S004

È05 Secondary Card Format—Even-Parity Checking

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Even Parity
Position

1 – 40

The position of the even-parity 'checksum'.

01

(U.K. ACPO = 00)

Even Parity
Start

1 – 40

This is the position of the first data-bit to be
included for even-parity checking.

02

(U.K. ACPO = 00)

Even Parity
Length

0 – 40

This is the number of bits to be included for
even-parity checking.

12

(U.K. ACPO = 00)

Odd/Even Parity checking:

This feature (which applies only to Wiegand-format cards) helps prevent card misreads.

To disable parity checking:

Set the 'Parity Length' to 0 (zero).

S005

È00 Dialer Selections

Keypad Selections

(left to right on keypad screen) N America Example:


Name

Selections

Description

Regional Settings Default

Dialer Account
Number (Primary)

Enter the dialer account
number.

The monitoring station receiver
number that will identify the
security system.

000000

N America

1

European 3
U.K. ACPO

4

Aus/NZ 4
China/H.K. 3
Netherlands 3
Switzerland 3

Telco Modem Type

1 = Bell 103 *, 2 = 8OP STU *,
3 = WWMODEM *,
4 = WWMODEM 8OP STU
Enter the selection for the
modem used.
*

Discontinued modems. This

programming is available for previously
installed versions.

STU = Subscriber Terminal Unit
WW = World Wide

France 3
N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Telco Alarm Report
Mode

0= not used, 1= primary, 2=
backup, 3 = dual
4 = future

NOTE:

Entering a “0” in an

existing system will turn the
dialer of and reset all messages
in the system.

France 0
N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
France 0

Telco Format

0 = SIA Level 2, 1 =CID, 2=SIA
Level 3 (future), 3=Future

France

9

(yes)

000000

·

1

·

0

·

0

·

0

†

9

È

Save S005

И

00