xL Regional Settings Guide

21-3609E rev1.0

66

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Hold PIN Prompt

9

(yes)

(no)

Personal access device (card,
fob) must be held at e.g. keypad
reader and a PIN must be
entered for a response.

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Disable Single on
Badge-Hold

9

(yes)

(no)

This determines whether or not
the action defined under 'single'
(in or out of schedule) will also
occur on a badge-hold action.
Not selected: Badge-hold
produces action defined under
'single' is included.
Selected: Badge-hold action
occurs by itself.

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Disarm Card + PIN

9

(yes)

(no)

Must also use PIN to turn
protection off after using access
device (card, fob) at keypad with
internal reader.

France

□ (no)

M0xx

È07 Keypad Selections

NOTE: “xx” represents the module number.

WARNING:

These Access Control features are only available with the addition of the “Feature Expansion Board”.

(left to right on keypad screen) N America Example:

Pressing the keypad button under È

?

will display the type of module and the module’s input and output ranges.

Name

Selections

Description

Regional Settings Default

Reader Defined

9

(yes)

(no)

†

(no)

Card Lockout
Schedule

00 = No scheduled lockout
01 – 250 Schedule

A schedule to specify when card
access will be blocked

000

Enable or Disable
Cards of Type

0 = None
1=Escort Req’d, 2 =non-
permanent users. 3 =all users

0

Enable or Disable
Mode

If enabling reader, see Note *1.
If disabling reader, see Note *2.

Note *1: If enabling reader,
0=enable for 4 hrs, 1=enable for
8hrs, 2=enable for 12 hrs,
3=enable for 24 hrs, 4=enable
for 1 week, 5=enable until
midnight tonight, 6=enable
permanently, 7=enable until out
of schedule according to
schedule 50.
Note *2: If disabling reader,
0=disable card permanently,
1=disable card but set it so that
it can be re-enabled later at an
enabling station, 2= disable card
permanently and trigger auxiliary
output , 3= disable card enable
re-enroll and trigger auxiliary
output, 4 to 7 = not used, same
as 1 (room for future expansion)

0

NOTE:

Programming selections whose boxes are grey are not available for this version.

†

·

000

·

0

·

0

·

†††

···

È

Save

È

? M001

И

07

Advertising