Document revision history, Disclaimer, Copyrights and trademarks – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 4

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

ii

General Message Format ...............................................................................................................106

SIA Level II Format.....................................................................................................................106

Contact ID Format ......................................................................................................................106

Door Activity....................................................................................................................................106

Event Message Reference: Sorted by SIA Code...........................................................................107

Event Message Reference: Sorted by CID Code ..........................................................................108

European and ACPO Installations..............................................................................................110

ACPO Installation Requirements ....................................................................................................110

Index .......................................................................................................................................................... 113

NOTE:

Regional Settings firmware v4.53 or greater is only available with xL Systems. Monitor ISM and Monitor

AFx are not supported.

Programming selections whose boxes are grey are not available for this version.

Disclaimer

This document contains proprietary information of
CSG Security Inc. / Sécurité CSG Inc., and may not be
reproduced in any form or disclosed to any third party
without written approval of a duly authorized
representative of CSG Security Inc./Sécurité CSG Inc.

All products are warranted against defects in
workmanship or materials (details available upon
request). Installers are responsible for knowing and
complying with any local regulatory fire and building
codes. In the interests of improving quality and
design, the right to amend specifications without given
prior notice is reserved.

Do Not Alter Components: Altering units, or removing
components without written consent by the manufacturer may
void warranties and/or cause the specific device to no longer meet
local regulatory requirements.

Copyrights and Trademarks

®™ All trademarks are acknowledged as the property
of their respective owners.

© Copyright 1999-2009
CSG Security Inc.

/

Sécurité CSG Inc.

All rights reserved.

Document Revision History

Refer to the Table of Contents or Index to locate the
following updates or perform a Search for key words:
Rev1.0 Additions/Deletions

• First publication.



These instructions are used for both the Open xL and Monitor xL versions of xL Security Equipment.

A red dot on xL equipment and its packing material will identify it as the Open xL version.

Model numbers ending with a “T” will identify the Open xL equipment versions.

Open xL and Monitor xL versions of xL Security Equipment can not be used together.

VBUS devices can be used with both Open xL and Monitor xL versions of xL Security Equipment. VBUS devices are not used with
ISM equipment.

Only Monitor xL Security Equipment can be used to upgrade a Monitor ISM security system. The Open xL version is not used with
Monitor ISM equipment.

Only Monitor xL Director Software can be used to upgrade Director Software that communicates with a Monitor ISM security system.
The Open xL Director Software is not used with Monitor ISM equipment.

Open xL, Monitor xL and ISM systems can communicate to the same HSC-IP Receiver. However, the Open xL system will require an
Open xL HSC-IP Module to communicate with the HSC-IP Receiver.

A regular IP Module (non HSC-IP) can be used by an Open xL, Monitor xL or ISM system if they are only communicating to the
Monitor xL or Open xL Director Software.

Only Monitor xL Director Software can be used with a Monitor xL Security System.

Only Open xL Director Software can be used with an Open xL Security System.

Confirm that the correct firmware is used when upgrading a security system’s firmware. Upgrading an Open xL security system
firmware with Monitor xL firmware can disrupt operations on a system wide scale. An Open xL system must be upgraded with Open xL
firmware. The same applies to only using Monitor xL firmware to upgrade a Monitor xL system.

Advertising