Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 35

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

31

N America

0

European

1

U.K. ACPO

1

Aus/NZ

1

China/H.K.

1

Netherlands 1
Switzerland

1

AC Sync

0=60 Hz, 1=50 Hz, 2=No sync
required, 3=DC supply

Synchronization with AC line to
maximize internal clock
accuracy. With an unstable AC
source, select "2: AC-No Sync"
('AC failure' will be reported if
the frequency drops below 12.5
Hz). With a DC source, be sure
to disable E003 (AC Trouble)
under "Equipment Settings".
DC supply option will not detect
power failure condition and will
not have a time base sync

France

1

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

AC Brownout Mode

0=None, 1=Local alarm,
2=Alarm+report, 3=Report only


France 0


S001

È06 Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

N America

001

European 001
U.K. ACPO

001

Aus/NZ 001
China/H.K. 001
Netherlands 001
Switzerland 001

VBUS Panel Output
Base

See: Main Panel Output
Examples:

next

What number the outputs that

will be used on the main

controller’s VBUS connection

will start at.

France 001
N America

001

European 001
U.K. ACPO

001

Aus/NZ 001
China/H.K. 001
Netherlands 001
Switzerland 001

Paging Output Base

See: Main Panel Output
Examples:

next

What number the outputs that

will be used on the paging

system will start at.

Also see S005:08, 09

France 001
N America

001

European 001
U.K. ACPO

003

Aus/NZ 001
China/H.K. 001
Netherlands 001
Switzerland 001

Output Base for:

World Wide Modem
with 8 output STU
REDCARE interface or
8 output STU
REDCARE interface

STU = Subscriber
Terminal Unit

See: Main Panel Output
Examples:

next

What number the outputs that
will be used with the main
control board output plug in
boards will start at.

France 001

Main Panel Output Examples:

If the main panel’s 2 relay outputs have a base of 1; this is the base number they

start at. Assigning outputs to them would require the minimum amount of 4. Outputs 3 and 4 are not used. The next
set of outputs could be the World Wide Modem with 8 output STU plugged in to the main controller modem port. Its
base number would then be 5. 8 outputs assigned to it would make its output range 5 to 12. Next would be if an 8
output VBUS board was connected to the main controller VBUS port. Its base number would be 13 and assigned 8
outputs making its range 13 – 20. Instead of modem outputs and one VBUS output board, 2 VBUS output boards
could be used in the same way. More outputs can follow through module programming after the main controller or
pager outputs can be added next. The pager output’s base number would then be 21 and could be assigned 4
outputs that would be 21 – 24 (maximum 16 pager outputs). Then output ranges for regular modules after the ones
assigned to the main control unit can be done.