Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 85

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

81

40

Doors Locked Out.

41 Doors

Held

Open.

42 Doors

Forced.

43

Door Tampers (door contact condition:
no EOL resistor etc.)

44 Doors

Open.

45 Doors

Secure.

46

Door Sensor Troubles (magnetic bond
sensor not ok)

47

Panic Token Detected.

48

Area “Empty” (User count <= minimum).

49

Area ”Full” (User Count >=Maximum).

50

No Detected Activity in Area.

51

Activity Detected in Area.

52

15 minutes prior to Scheduled “Arm to
ON” Level.

53

15 minutes prior to Scheduled “Arm to
STAY” Level.

54

15 minutes prior to Scheduled “Arm to
OFF” Level.

55

Area schedule is active.

56

Auto-command schedule is active.

57

Failed to close.

58

Any point in tamper in area.

59

Area armed with points bypassed.

60

Area Force Armed.

61

Invalid Card / PIN Lockout present.

62

Wandering Patient detected.

European Version

(Area)

63 Siren
64

Confirmed Alarm Strobe

65 Fire
66 Personal

Attack

67 Unconfirmed

Alarm

68

Set / Unset

69

Freezer / Fire Fault

70

Bypass in Effect

71 Confirmed

Alarm

Program Section

(“q”)

“P”

oint (

Inputs)

Section Range

(“nnn”)

Enter 001 – 128

Code

cc

Description

00

When point is NORMAL.

01

Any time the point is NOT NORMAL
(open, tamper, alarm)

02

When point is NOT NORMAL in OFF or
STAY (open, tamper, alarm)

03

When point is NOT NORMAL in ON
(open, tamper, alarm)

04

When point is in ALARM

05

When point is BYPASSED

06

When the time delay is active (Pre-alarm
Warning).

07

Point is in Tamper.

08

Point is in Delay. Follows a Custom Pt
Type that has a time delay.

09

Positive confirmation of Command Point
activation.

Program Section

(“q”)

“B”

Output State

Section Range

(“nnn”)

Enter 001 – 128

Code

cc

Description

00

An actual output is on.

01

Equation Output is TRUE

02

Manual Command is in effect from the
Director software Outputs Section,
Control & Status.

WARNING:

Access Control related outputs can only be used with

the addition of the “Feature Expansion Board”.

Program Section

(“q”)

“R”

Doors

Section Range

(“nnn”)

Enter 001 – 032

Code

cc

Description

00 Door

Unlocked

01 Door

Locked

Out

02 Door

Held

Open

03 Door

Forced

04

Door Tamper (door contact condition: no
EOL resistor etc.)

05 Door

Open

06 Door

Secure

07

Door Sensor Trouble (magnetic bond
sensor not ok)

08

Door Blocked by Interlock Condition

09

Wandering Patient Detected

10

Door entry Delay in Effect

Program Section

(“q”)

“F”

loors

Section Range

(“nnn”)

Enter 001 – 124

Code

cc

Description

00 Floor

Desecure

Program Section

(“q”)

“M”

odule

Section Range

(“nnn”)

Enter 01 – 24

Code

cc

Description

00 On

Line

01 Tamper
02

Comms Trouble (Substitution & Comms)

03 Battery

Trouble

(Module)

04

User logged on to e.g. LCD keypads

Program Section

(“q”)

“C”

Suite

Section Range

(“nnn”)

Enter 01 – 24

Code

cc

Description

00 Alarm
01 Fire
02 Tamper
03

Siren / Sonalert

04

Module Communications Trouble

05

Suite Normal (No Alarm, Fire, Tamper,
Siren / Sonalert, Comms Trouble)

06

Suite in STAY level.

07

Suite in ON level.

08

Suite in STAY or ON level.