Default programmable outputs for regional settings, Example 8: flash a led when a condition is true – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 81

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

77

Example 7: Simple Two Term OR Equation with Timed Output

Configurable only with Director software and Sent to Panel

Bxxx:00 “? A001.15 Query ”

- Area 1 is not ON

Bxxx:01 “? A002.14 Query ”

- Area 2 is OFF

Bxxx:02 “L 00 Logic ”

- Logical OR operator

– additional screen generated with Director software.

Bxxx:03 “T 012 Timer ”

- Timed output, 2 minutes

additional screen generated with Director software.

1. Output Bxxx will turn on for 2 minutes when area 1 changes from on or when area 2 goes off from some other

state.

2. The output will not turn back on again after the 2 minutes expire until area 1 goes On and Area 2 is either STAY or

ON.

3. After these two conditions are met, the output will turn back on as noted in point 1.

Example 8: Flash a LED when a Condition is True

Configurable only with Director software and Sent to Panel using “System – Special Outputs

Bxxx:00 “? A016.24 Query ”

- A point is bypassed in Area 16

Bxxx:01 “? S001.00 Query ”

- Turns 1 sec On, 1 sec Off

Bxxx:02 “L 01 Logic ”

- Logical AND operator

Bxxx:03 “T 000 Timer ”

- Follow (Normal)

• When a point is bypassed in area 16, the output will flash 1 second on, 1 second off.

• This is achieved by the logical AND of the area condition query and the special On /Off effect available in System –

Special Outputs programming.

Example 9: (Complicated) Flash a LED for 45 Minutes after a Panic Token is Detected in an
Area

Configurable only with Director software and Sent to Panel using “System – Special Outputs

B001:00 “? A001.47 Query ”

- Panic Token used in Area 1

B001:01 “T 019 Timer ”

- Timed Output, 45 minutes

B002:00 “? S001.00 Query ”

- Turns 1 sec On, 1 sec Off

B002:01 “? B001.00 Query ”

- Output 1 is ON

B002:03 “L 01 Logic ”

- Logical AND operator

B002:04 “T 000 Timer ”

- Follow (Normal)

• 2 separate outputs are used to perform this procedure.

• A 45 minute timer is applied to panic tokens detected in area 1 in e.g. output # “B001”.

• The output state of B001 (timed output based on panic token in area 1) is used to logically “AND” additional output #

e.g. B002 with the Special System 1 second On/Off selection. The important detail is that we use Follow (Normal)
for output B002, in order for the timer not to re-trigger.

Default Programmable Outputs for Regional Settings

Output # / Location

Regional Setting Default

Default Codes / Setting

Meaning / Operation

B001:00 (motherboard)
B001:01

N America

“? S000.07 Query ”
“T 000 Timer ”

- Follows Alarm Siren
- Follow (Normal)

B001:00 (motherboard)
B001:01

European

“? S000.07 Query ”
“T 000 Timer ”

- Follows Alarm Siren
- Follow (Normal)

B001:00 (motherboard)
B001:01

Aus/NZ

“? S000.06 Query ”
“T 000 Timer ”

- Follows ALARM (BURG / EMERG) & FIRE
siren steady.
- Follow (Normal)

B001:00 (motherboard)
B001:01

China/H.K.

“? S000.07 Query ”
“T 000 Timer ”

- Follows Alarm Siren
- Follow (Normal)

B001:00 (motherboard)
B001:01

Netherlands

“? S000.06 Query ”
“T 000 Timer ”

- Follows ALARM (BURG / EMERG) & FIRE
siren steady.
- Follow (Normal)

B001:00 (motherboard)
B001:01

Switzerland

“? S000.07 Query ”
“T 000 Timer ”

- Follows Alarm Siren
- Follow (Normal)

B001:00 (motherboard)
B001:01

France

“? S000.07 Query ”
“T 000 Timer ”

- Follows Alarm Siren
- Follow (Normal)

B002:00 (motherboard)
B002:01

N America

“? S000.05 Query ”
“T 000 Timer ”

- When system is IN ALARM.
- Follow (Normal)