Netherlands, Switzerland, France – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 9

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

5

Entry/Exit Delay The system timer delay tables for a China/HK regional setting replaces 45 seconds with 40
seconds and 90 seconds with 100 seconds for “CCC” requirements.

Netherlands

Dual Custody A service user entering their user codes must also have an end user enter their user codes for the
service user to be able to service the system or access system programming through the keypad.

Input Trouble Condition Acknowledge When protection inputs have had a trouble condition, example: have had an
end of line resistor failure, the condition must be acknowledged.

The trouble condition will continue to appear in the normal rotating keypad screens.

In order to clear this condition, a service user must open the control box to activate its tamper switch and enter
their codes along with the end user’s codes at the keypad.

Equipment Failure or Tamper Condition Acknowledge When a tamper or equipment failure condition has occurred,
a service user must enter their code along with the end user to acknowledge the condition. The keypad will
continue to display a trouble condition until this is done. Turning protection on will not be allowed if there is an
unrestored tamper or equipment failure condition.

Split Logs When the History menu is accessed on the keypad, the selections “All”, “Intrusion” and
“Category\Area\Area condition: On, Off, Stay\Area History” are available.

Switzerland

Dual Custody A service user entering their user codes must also have an end user enter their user codes for the
service user to be able to service the system or access system programming through the keypad.

Equipment Failure or Tamper Condition Acknowledge When a tamper or equipment failure condition has occurred,
a service user must enter their code along with the end user to acknowledge the condition. The keypad will
continue to display a trouble condition until this is done. Turning protection on will not be allowed if there is an
unrestored tamper or equipment failure condition.

Split Logs When the History menu is accessed on the keypad, the selections “All”, “Intrusion” and
“Category\Area\Area condition: On, Off, Stay\Area History” are available.

Keypad Lights The red protection status light and the yellow system trouble light are disabled for the Switzerland
version. Only the green keypad light for power on is enabled.

France

Dual Custody A service user entering their user codes must also have an end user enter their user codes for the
service user to be able to service the system or access system programming through the keypad.

Split Logs When the History menu is accessed on the keypad, the selections “All”, “Intrusion” and
“Category\Area\Area condition: On, Off, Stay\Area History” are available.