Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 101

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

97

R001

È09 Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

N America

00

European

00

U.K. ACPO

00

Aus/NZ

00

China/H.K.

00

Netherlands 00
Switzerland

00

Door Forced / Held
Time

Delay Table

NOTE:

Programming selections

whose boxes are grey are not
available for this version.

France

00

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Door Circuit

0=NC
1=NC/EOL
2=NO/EOL & Form-C SEOL
3=Form-C DEOL

The type of circuit/wiring being
used with the door contact.

France 0
N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

RTE Circuit
(request to exit)

0=NC
1=NC/EOL
2=NO/EOL & Form-C SEOL
3=Form-C DEOL

The type of circuit/wiring being
used with the RTE input.

France 0
N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Reader Tamper
Circuit

0=NC
1=NC/EOL
2=NO/EOL & Form-C SEOL
3=Form-C DEOL

The type of circuit/wiring being
used with the reader tamper.

France 0
N America

0

European

0

U.K. ACPO

0

Aus/NZ

0

China/H.K.

0

Netherlands 0
Switzerland

0

Auxiliary Circuit

0=NC
1=NC/EOL
2=NO/EOL & Form-C SEOL
3=Form-C DEOL

The type of circuit/wiring being
used with the aux. input.

France

0

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Do Not Lock on Door
Closure

9

(yes)

(no)

NOTE:

Programming selections

whose boxes are grey are not
available for this version.

France

□ (no)

N America

□ (no)

European

□ (no)

U.K. ACPO

□ (no)

Aus/NZ

□ (no)

China/H.K.

□ (no)

Netherlands □ (no)
Switzerland

□ (no)

Insertion Reader

9

(yes)

(no)

France

□ (no)

Advertising