Save, M001 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 68

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

64

Module Selection Numbers
1 = Map Pod, 2 = Fx LCD, 3 = Other, 4 = V1 Access, 5 = V1 Wireless, 7 = ISM LCD*, 8 = ISM Input/Output, 9 = PDC,
10 = *HSC, 11 = Suite Security 8 zone, 12 = TDC, 14 = V2 Access, 15 = Elevator, 16 = Suite Security 2 zone, 17 = V2
Wireless (FA400), 18 = MF-FA Wireless, 19 = ITI SuperBus Wireless, 20 = IPlus, 21 = C2000, 22 = Inova PointMux,
23 = standard xL LCD, 24 = xL LCD GProxII (keypad reader), 25 = xL LCD (external reader), 29 = xL Input/Output, 32
= xL Power Supply, 33 = Wireless 868+900, 34 = Smart/Vigil, 35 = Wireless 868+900+(Australia), 36 = 2050 MIL250
9600 baud only, 37 = 2050 DC, 38 = 2050 IO16, 39 = 2050 I32, 40 = 2050 O32.

*NOTE: Regional Settings does not support Monitor ISM.

*

HSC (High Security Communications) is a proprietary communications of CSG Security Inc. and not used in all markets.

M0xx

È02 Annunciation Map

Keypad Selections

(left to right on keypad screen)

NOTE: “xx” represents the module number.
Name

Selections

Description

Regional Settings Default

Area 1 to Area 16

9

(yes)

(no)

AnnuAreaMap defines which areas the
module can alert sirens, sonalerts and
other sound notifications from.

Area 1:

9

(yes)

Area 2 – 16:

(no)

M0xx

È03 Arm/Disarm Map

Keypad Selections

(left to right on keypad screen)

NOTE: “xx” represents the module number.
Name

Selections

Description

Regional Settings Default

Area 1 to Area 16

9

(yes)

(no)

Defines which areas can be armed /disarmed
from this e.g. keypad.
Required for Area Group Mode assignments
S001È08

Area 1:

9

(yes)

Area 2 – 16:

(no)

M0xx

È04 Exit Delay Map

Keypad Selections

(left to right on keypad screen)

NOTE: “xx” represents the module number.
Name

Selections

Description

Regional Settings Default

Area 1 to Area 16

9

(yes)

(no)

Defines which areas also have an exit
delay when the area this keypad is
assigned to is armed.

Area 1:

9

(yes)

Area 2 – 16:

(no)

M0xx

È05 Keypad Selections

NOTE: “xx” represents the module number.

WARNING:

These Access Control features are only available with the addition of the “Feature Expansion Board”.


(left to right on keypad screen) N America Example:

Pressing the keypad button under È

?

will display the type of module and the module’s point and output ranges.

Name

Selections

Description

Regional Settings Default

Schedule

0-250

000

N America

07

European 05
U.K. ACPO

05

Aus/NZ 00
China/H.K. 05
Netherlands 05
Switzerland 05

Single Badge In-
Schedule Mode

00=None, 01=Auto logon, 02=Auto
arm ON, 03=Auto Arm STAY,
04=Auto Disarm STAY, 05=Auto
Disarm OFF, 06=Toggle OFF-
STAY, 07=Toggle OFF-ON,
08=Toggle STAY-ON, 09=Extend
Exit Delay, 10=Auto Work Late.

France 05
N America

07

European 05
U.K. ACPO

05

Aus/NZ 00
China/H.K. 05
Netherlands 05
Switzerland 05

Single Badge Out of
Schedule Mode

Same selections as “Single Badge
In Schedule Mode”.

France 05

000

·

07

·

07

·

00

·

00

·

È

Save

È

? M001

И

05