Program section: s001 (system wide selections), Save s001 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 30

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

26

Advanced Program Sections, Sub Program Sections and Selections

NOTE:

For quick reference to locate Advanced Programming Section Selections, consult the Index at the back of this

manual.

WARNING:

Access, Elevator and Suite Security selections are only available with the addition of the

“Feature Expansion Board” to the System.

Programming selections whose boxes are grey are not available for this version.

Advanced Programming System Global Timer Delay Table Codes

00: undefined;
01: 1 sec;
02: 2 sec;
03: 3 sec;
04: 5 sec;

05: 10 sec;
06: 15 sec;
07: 20 sec;
08: 30 sec;
09: 45 sec;

(09: China/
HK=40 sec)
10: 60 sec;
11: 90 sec;
(11: China/
HK=100 sec)

12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;
16: 15 min;

17: 20 min;
18: 30 min;
19: 45 min;
20: 60 min;
21: 90 min;

22: 2 hr;
23: 4 hr;
24: 6 hr;
25: 8 hr;
26: 10 hr;

27: 12 hr;
28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week

Program Section: S001 (System Wide Selections)

S001

È00 Keypad Selections

(left to right on keypad screen) N America Example:


Name

Selections

Description

Regional Settings Default

N America

14 (5 min)

European

17 (20 min)

U.K. ACPO

16 (15 min)

Aus/NZ

14 (5 min)

China/H.K.

22 (2 hr)

Netherlands 17 (20 min)
Switzerland

17 (20 min)

Burglary Siren Time

Delay Table
Maximum = 2 hours.

How long a siren in the system
will sound.

France

17 (20 min)

N America

03

European 03
U.K. ACPO

03

Aus/NZ 03
China/H.K. 03
Netherlands 03
Switzerland 03

Number of panel
inputs

Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “01” for 4
inputs.
4 X 2 = 8. Enter “02” for 8 inputs.
4 X 3 = 12. Enter “03” for 12 inputs.
4 X 4 = 16. Enter “04” for 16 inputs.
4 X 5 = 20. Enter “05” for 20 inputs.

For VBUS input boards
connected to the main
controller VBUS port. 20 inputs
maximum. 12 on main board
and 1 VBUS input boards
possible.

France 03
N America

01

European 01
U.K. ACPO

03

Aus/NZ 01
China/H.K. 01
Netherlands 01
Switzerland 01

Number of panel
outputs

Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4
outputs.
4 X 2 = 8. Enter “2” for 8 outputs.
4 X 3 = 12. Enter “3” for 12 outputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.
4 X 6 = 24. Enter “6” for 24 inputs.
4 X 7 = 28. Enter 7” for 28 inputs.

For VBUS output boards or
modem output boards
connected to the main
controller VBUS port. 26
outputs maximum. Program for
28 outputs and skip outputs 27
– 28. 2 relays on main board
and 2 VBUS output boards
possible or 1 VBUS output
board and one 8 output modem
board. Also see S001:06 -07.

France 01

N America

0

European 0
U.K. ACPO

0

Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0

Panel Type

0 = xL, 1 = MONITOR ISM, 2 =
Future, 3 = Future.

NOTE:

Regional Settings does not

support Monitor ISM.

France 0

14

·

03

·

01

·

0

·

1

·

1

·

0

È

Save S001