Program section: p001 (inputs), Input point-type reference, Save – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 72: P001, Xl regional settings guide, Form “c” single resistor, Example: 201 point type, Example: 201 area this input is assigned to

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

68

Program Section: P001 (Inputs)

Pxx1

È00 Keypad Selections

NOTE: “xx1” represents the input number.

(left to right on keypad screen) N America Example:

Pressing the keypad button under È

?

will display the module the point is associated with and the module’s point

range.
Name

Selections

Description

Regional Settings Default

Circuit Type

0: N/C (no EOL)
1: N/C with 2.2k EOL
2:

Form “C” single resistor

EOL

& N/O with 2.2k EOL
3: Form C—dual 2.2k

First digit of the input’s first 3
digit code for standard types
only. Refer to S007:00 for
Custom Circuit Types.
A “000” 3 digit code is an
undefined input.

Example: 201

Point Type

01 - 33: See the Input Point Type
Reference table.
80 - 99: Custom types
programmed in section: T080 -
T099.

Second 2 digits of the input’s
first, 3 digit code
A “000” 3 digit code is an
undefined input.

Example: 201

Area this input is
assigned to.

01

Buffer Area

A secondary area that shares
Entry/Exit doors with the above
first area. If not a Buffer Area,
enter the same area number as
above, again here.

01

Pxx1

È1 Keypad Selections

(left to right on keypad screen)

NOTE: “xx1” represents the input number.
Name

Selections

Description

Regional Settings Default

Input # 1 Label

16 available characters

The input name that will appear
in input Status, Alarm menus,
etc. Edit the same as the
Greeting Message, S001:04

Example:
FRONT DOOR
(16 available characters)

Input Point-Type Reference

Point Type

(

###

)

Class

Monitored for these

Area Arming Level(s)

Monitoring Style

By-

pass Chime Tx Off

Tx

Stay Tx On

Sonlrt

Off

Sonlrt

Stay

Sonlrt

On

Siren

Off

Siren

Stay

Siren

On

01

(Entry Door)

Burg

Stay & On

Entry/Exit Door

9

– 9

9

– 9

9

– 9

9

02

(Entry Route)

Burg

ON Only

Entry/Exit Route

9

– – – 9 – 9 – – 9

03

(Perimeter)

Burg

Stay & On

Immediate

9

9

– 9

9

– 9

9

– 9

9

04

(Interior Motion) Burg

ON only

Immediate

9

– – – 9 – 9 – – 9

05

(Motion–FAP)

Burg

ON only

FAP

9

– – – 9 – 9 – – 9

FAP:

(False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and immediately resets, a 20

minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.

06

(Day Warning)

Burg

24hr

Immediate

9

– – – 9

9

9

9

– – 9

07

(24hr Burglary)

Burg

24hr

Immediate

9

– 9

9

9

9

9

9

9

9

9

10

(Fire - A)

Fire-A 24hr

Immediate

– – 9

9

9

9

9

9

9

9

9

11

(Fire - Delayed) Fire

24hr

15s delay

– – 9

9

9

9

9

9

9

9

9

12

(Fire - Immed)

Fire

24hr

Immediate

– – 9

9

9

9

9

9

9

9

9

13

(Hold-up)

holdup 24hr

Immediate

– – 9

9

9

– – – – – –

14

(Aux Alert)

Emerg 24hr

Immediate

– – 9

9

9

9

9

9

9

9

9

20

(Supervisory)

Spvsr 24hr

Immediate

9

– 9

9

9

9

9

9

– – –

30

(Local - 24hr)

Burg

24hr

Immediate

9

– – – – 9

9

9

9

9

9

31

(Local-Stay&On) Burg

Stay & On

Immediate

9

9

– – – – 9

9

– 9

9

32

(Future Use)

Burg

Future Use

Future Use

9

9

– – – – – 9 – – 9

33

(Local - ON only) Burg

ON only

Immediate

9

9

– – – – – 9 – – 9

80 - 99

(Custom)

Custom point types as defined in T080 - T099. Custom point types provide full control over input point characteristics, plus additional
features including arm/disarm keyswitch operation, and setting up garage door sensors, Vault/Safe class input points, plus guard-tour
points, and work-late buttons.

201

·

01

·

01

·········

È

Save

È

? P001

И

00

Advertising