Outputs, Simplified regional settings output defaults – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 24

Advertising
background image

xL Regional Settings Guide

21-3609E rev1.0

20

Outputs

Select Output?
◄ B001

►S000.07 ↓Ok

Pre-programmed Output
numbers like B001 will
display with their pre-

programmed code: e.g. S000.07. This is an output code that is programmed in Advanced Programming. Press

Ok to

edit the pre-programmed output using the following simplified output selections.

Select Output

Select Group
(Program Section)

Select Condition

Select Operation

B001 – B128

System

Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Areas
Select Area #

On, Stay 2, Stay 1, Stay 1 and 2, Off, Not On, Not
Off, Alarm, Was (In) Alarm

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Protection Points
Select Point #

Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Outputs
Select Output #

Real OP (output) On, Equation is True, Manual
Command

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Modules
Select Module #

On Line, Tamper, Comms Trbl, (Communications
Trouble), Battry Trbl (Battery Trouble), User
Logged On,

Toggle, Normal, Time
Delay or Inverted

B001 – B128

Equipment Points
Select Point #

System Tmpr (Tamper), Low/No Battery, AC
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.

Toggle, Normal, Time
Delay or Inverted

Simplified Regional Settings Output Defaults

Select Output

Regional Setting
Default

Select Group
(Program Section)

Select Area, Point,
etc.

Select Condition

Select
Operation

B001

(

Relay 1 on

motherboard)

N America
(Advanced
programming
code: S000.07)

System

Fire Cadence

Normal

B001

(

Relay 1 on

motherboard)

European
(S000.07)

System

Fire Cadence

Normal

B001

(

Relay 1 on

motherboard)

Aus/NZ
(S000.06)

System

Siren Normal

B001

(

Relay 1 on

motherboard)

China/H.K.
(S000.07)

System

Fire Cadence

Normal

B001

(

Relay 1 on

motherboard)

Netherlands
(S000.06)

System

Siren Normal

B001

(

Relay 1 on

motherboard)

Switzerland
(S000.07)

System

Fire Cadence

Normal

B001

(

Relay 1 on

motherboard)

France
(S000.07)

System

Fire Cadence

Normal

B002 (

Relay 2

on motherboard

)

N America
(S000.05)

System

In Alarm

Normal

B002 (

Relay 2

on motherboard

)

European
(S000.05)

System

In Alarm

Normal

B002 (

Relay 2

on motherboard

)

Aus/NZ
(S000.57)

System

Fully On (Strobe)

Normal

B002 (

Relay 2

on motherboard

)

China/H.K.
(S000.05)

System

In Alarm

Normal