V001 - v032 (elevators/lifts), F001 - f124 (floors), Z001 - z003 (shared user data) – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 109

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

105

V001 - V032 (Elevators/Lifts)

Elevator controller modules provide security and monitoring features for elevator (lift) cabs and associated
floors. These units can be set up only through the Director Software (subject to your software version and
licensing agreement). For details, refer to the on-line help or User's Guide for your Director Software.

Each system can include up to 32 elevators, and a total of up to 124 access-controlled floors. Exception: The elevator capacity
is shared with doors (max. 32 combined). Doors also share the elevator numbering (and panel memory space). Numbers
already defined as doors will not be available for elevators.
With access-controlled elevators, floor call-buttons are disabled until an authorized person presents their access card. When the
card is presented, the specific floors for that person will become available.
UL / ULC Listed Installations: As of this writing, UL and ULC testing is pending on elevator (lift) controllers and related features.

F001 - F124 (Floors)

Systems with elevator controllers can include up to 124 access-controlled floors. These can be in a single
building, or the combined total for multiple buildings. Elevator controllers and floors can be set up only through
the Director Software (subject to your software version and licensing agreement). For details, refer to the on-line
help or User's Guide for your Director Software.

Floors can be set to allow free access during certain times based on a chosen schedule. As well, the status & control feature of
the Director Software allows manually setting floors to allow free access, or apply controlled-access, as desired.
UL / ULC Listed Installations: As of this writing, UL and ULC testing is pending on elevator (lift) controllers and related features.

Z001 - Z003 (Shared User Data)

Allows Users, Authority Levels and Holidays to be shared across multiple accounts using Director version 4.2.
With Director V4.2, this feature is limited to panel feature-set 2, 3, and 4 (1 panel per account, max. 1000 users,
etc.). Information for this type of system set-up is available in the v4.2 Director’s User Guide.
Shared Users, Authority Levels and Holidays are considered to be under Director control and not panel control.
Programming for this selection is not done in the LCD keypad configuration screens. Programming is only done
for these selections with the use of the Director software and sent to the panel.

Initiating a “Get from Panel” from the Director software cannot be done for the following reasons:

Shared Users and Holidays

If changes for these selections have been made at the panel using an LCD keypad and a Get from Panel is done
at the Director software, the new information in the panel will be ignored and overwritten with the server’s old
information.

Shared Authority Levels

• Shared Authority Levels that are not in the panel will have any new information that has been entered into the

server data base for their Areas and Schedules cleared.

Panels with Firmware Earlier than v4.2 and a Get from Panel is Done:

1. If a Shared User has been edited at the panel, only their PIN will be updated. The server will replace any of the

other user’s data with the server’s old information.

2. If a Shared Authority Level is deleted at the panel, any new and valid information for the Authority Level’s Areas

and Schedules will be cleared at

the server and the panel.

Keypad Operations at Panels with v4.2 Firmware

1. Only a Shared User’s PIN can be edited at the panel and only by that Shared User.

Shared Authority Levels cannot be deleted at the panel.