Save s004 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 45

Advertising
background image

21-3609E rev1.0

xL Regional Settings Guide

41

S004

È01 Secondary Card Format—Site Codes

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

1st Site Code
Value

0000 – 9999

The 1st of up to three site/system codes
that can be encoded within access
tokens to be used at the site.

0000

2nd Site Code
Value

0000 – 9999

The 2nd of up to three site/system codes
that can be encoded within access
tokens to be used at the site.

0000

3rd Site Code
Value

0000 – 9999

The 3rd of up to three site/system codes
that can be encoded within access
tokens to be used at the site.

0000

If site code checking is enabled for a secondary card/token format, cards encoded with any one of up to three site code values can be used at the
site. (All other cards will be globally denied access.)


S004

È02 Card Version-Information (Secondary)

Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

Check for
Version No.

9

(yes)

(no)

Whether or not secondary-format tokens
will be checked for a current version
number.

†

(no)

Version No.
Position

1 – 40

The position of the 1st digit for the
version number on these access tokens.

02

(U.K. ACPO = 01)

Version No.
Length

1 – 16

The length of the version number for
secondary-format tokens (number of
digits).

04

(U.K. ACPO = 01)

This feature requires V1.5 door/elevator controller firmware.


S004

È03 Secondary Card Format—Basic Settings

Keypad Selections
(left to right on keypad screen) Example:


Name

Selections

Description

Regional Settings Default

ID Number
Position

1 – 40

The position of the 1st digit for the ID
number on secondary-format access
tokens.

10

(U.K. ACPO = 07)

ID Number
Length

1 – 32

The length of the card ID-number for
secondary-format tokens.

16

(U.K. ACPO = 06)

No. of Bits /
Chars

1 – 40

The total number of bits (Wiegand) or
characters (Magstripe) in the card data.

26

(U.K. ACPO = 12)

Bits per
Character

1 – 8

The number of bits used to represent
each character (for magnetic stripe
cards).

8

(U.K. ACPO = 4)

Card/Token
Format

0=none, 1=future
(dallas), 2=weigand,
3=mag

The basic type of card or token
associated with the secondary card
format settings.

2

(U.K. ACPO = 3)

32-Bit / 9-Digit Card IDs: This requires V1.5 door/elevator controller firmware.

10

·

16

·

26

·

8

·

2

····

È

Save S004