xL Regional Settings Guide

27

N America

1

European 1
U.K. ACPO

1

Aus/NZ 1
China/H.K. 1
Netherlands 1
Switzerland 1

Module Bus

(SNAPP)

Baud Rate

0 = Auto Minimum (19K2), 1 = Auto
Maximum 38K4

The communications speed
between the main panel and
the expansion modules.

France 1
N America

1

European

1

U.K. ACPO

1

Aus/NZ

1

China/H.K.

1

Netherlands 1
Switzerland

1

Suite Security

(Condo)

Baud Rate

NOTE:

This feature is only

available with the addition of
the Director Software and
Feature Expansion Board.

0 = Auto Minimum (19K2), 1 = Auto
Maximum (38K4) 2 = 9600 (Auto
Minimum), 3 = future.

The communications speed
between the main panel and
the Suite Security modules.



NOTE:

Programming selections

whose boxes are grey are not
available for this version.

France

1

N America

0

European 1
U.K. ACPO

1

Aus/NZ 2
China/H.K. 1
Netherlands 1
Switzerland 1

Fallback Users

0: No access
1: All readable tokens
2: All with valid site code
3: 10 fallback users

Specific Cards granted access
if door controller is unable to
access the panel database.

Refer to S006È00-09 for the
10 Fallback Users.

France 1

S001

È01 Keypad Selections

(left to right on keypad screen)

Name

Selections

Description

Regional Settings Default

N America

WELCOME

European WELCOME
U.K. ACPO

CHUBB
SECURITY

Aus/NZ

CHUBB
SECURITY

China/H.K. WELCOME
Netherlands WELCOME
Switzerland WELCOME

Main screen
message

A greeting message that rotates
with any other main screen
messages. It can be customized
with the cursor under a letter or in a
blank space and pressing the
desired keypad button to enter a
particular letter/number. Use the left
and right arrow keys to maneuver
back and forth. Use the underscore
key “ _ “ on the keypad to insert a
space or clear a character.

France WELCOME

S001

È02 Keypad Selections

(left to right on keypad screen) N America Example:



Name

Selections

Description

Regional Settings Default

N America

000000

European 000000
U.K. ACPO

000000

Aus/NZ 000000
China/H.K. 000000
Netherlands 000000
Switzerland 000000

Panel Unique ID

(Panel Code, System ID)

A (non-zero) number to identify
the panel, site, or account to the
Director software. For an
existing system to be
synchronized with the Director
software, this must be a non-
zero value set here to match the
"Panel Code" in the software.

France 000000
N America

†

(no)

European

†

(no)

U.K. ACPO

†

(no)

Aus/NZ

†

(no)

China/H.K.

†

(no)

Netherlands † (no)
Switzerland

†

(no)

Unlock Doors on Fire
Alarm

NOTE:

This feature is only

available with the addition of
the Feature Expansion Board.

9

= Global Unlock

(no)

Will a fire alarm unlock all
controlled doors in the
facility?

France

†

(no)

000000

·

†††††††††