Uk default programmable outputs – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual

Page 82

Advertising
background image

78

xL Regional Settings Guide

21-3609E rev1.0

B002:00 (motherboard)
B002:01

European

“? S000.05 Query ”
“T 000 Timer ”

- When system is IN ALARM.
- Follow (Normal)

B002:00 (motherboard)
B002:01

Aus/NZ

“? S000.57 Query ”
“T 000 Timer ”

- Strobe
- Follow (Normal)

B002:00 (motherboard)
B002:01

China/H.K.

“? S000.05 Query ”
“T 000 Timer ”

- When system is IN ALARM.
- Follow (Normal)

B002:00 (motherboard)
B002:01

Netherlands

“? S000.57 Query ”
“T 000 Timer ”

- Strobe
- Follow (Normal)

B002:00 (motherboard)
B002:01

Switzerland

“? S000.05 Query ”
“T 000 Timer ”

- When system is IN ALARM.
- Follow (Normal)

B002:00 (motherboard)
B002:01

France

“? S000.05 Query ”
“T 000 Timer ”

- When system is IN ALARM.
- Follow (Normal)

B003:00 (keypad)
B003:01

N America

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

European

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

Aus/NZ

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

China/H.K.

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

Netherlands

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

Switzerland

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B003:00 (keypad)
B003:01

France

“? A001.01 Query ”
“T 005 Timer ”

- Function Key 1 on Area 1 1

st

keypad.

- Positive trigger, 10 sec delay.

B004:00 - B128:00
B004:01 - B128:01

N America

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

European

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

Aus/NZ

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

China/H.K.

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

Netherlands

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

Switzerland

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

B004:00 - B128:00
B004:01 - B128:01

France

“? 0000.00 Undef ”
“T 000 Timer ”

- Undefined output
- Follow (Normal)

UK Default Programmable Outputs

Output # / Location

Default Codes / Setting

Meaning / Operation

B001:00 (motherboard)
B001:01

“? S000.66 Query ”
“T 100 Timer ”

- ACPO Siren

B002:00 (motherboard)
B002:01

“? S000.67 Query ”
“T 000 Timer ”

- Confirmed Alarm (ACPO strobe)

B003:00 (keypad)
B003:01

“? A001.33 Query ”
“T 000 Timer ”

- When area Entry / Exit delay is in progress – provides a steady output
(STAY & ON).

B004:00 (WW STU)
B004:01

“? S000.60 Query ”
“T 100 Timer ”

- Personal ACPO Attack

B005:00 (WW STU)
B005:01

“? S000.61 Query ”
“T 100 Timer ”

ACPO Unconfirmed Alarm

B006:00 (WW STU)
B006:01

“? S000.62 Query ”
“T 000 Timer ”

ACPO Area Set / Unset

B007:00 (WW STU)
B007:01

“? S000.64 Query ”
“T 100 Timer ”

Bypass in Effect

B008:00 (WW STU)

“? S000.54 Query ”

Local AC (mains) failure.

Advertising