Nor-Cal SDC15 Controller User Manual

Page 115

Advertising
background image

5-65

Others

C72 [mode key function]: 7 (COM DI1 selection)
SP up ramp/down ramp:

Desired value

Setting points

The internal EV1 is substituted for the guarantee soak.
Therefore, “9999” is set to the hysteresis of Event 1 so that Event 1 is not turned
OFF after it has been turned ON even though the PV fluctuates.

DI Assignment (Internal Contact 1): Input/Output port setup

DI Assignment (Internal Contact 2):

Input/Output port setup

Chapter 5. DETAILED DESCRIPTION OF EACH FUNCTION

Logical AND of COM DI1 (a-contact)
and timer (b-contact)

Mode (RUN/READY) selection
contact

Reversed at this point since the
mode is the READY mode when
turned ON.

The timer start is self-retained at time-up so that
the timer is not restarted due to change in PV.

Timer start-up contact

Conditions for guarantee soak (ramp is completed and operation enters
within the deviation of the final SP.)