Chapter 5. DETAILED DESCRIPTION OF EACH FUNCTION

Password

The setting (changing) of the key lock, communication lock, and loader lock can
be set disabled using the password.

• When using only the key lock setting, the display can be made, but the setting

(changing) cannot be made.

• When locked with the password, the display and setting cannot be made.

• The display and setting of [Password 1A: PS1A] and [Password 2A: PS2A] can

be made only when [Password display: PASS] is “5” and the passwords of two
groups (1A and 1B, 2A and 2B) are matched.

• The display and setting of [Password1B: PS1b] and [Password 2B: PS2b] can be

made only when [Password display: PASS] is “5”.

• The value set in [Password1A: PS1A] is automatically set to [Password1B: PS1b].

• The value set in [Password2A: PS2A] is automatically set to [Password2B: PS2b].

Handling Precautions

• Before setting the passwords 1A to 2B, determine two hexadecimal

values to be used as passwords and take a memorandum of these

passwords to record them.

• [PASS] is used to prevent incorrect password setting by limiting the

display conditions of passwords 1A to 2B.

• When other values are set for passwords 1B and 2B after the values

to be used as passwords have been set for passwords 1A and 2A,

the passwords 1A and 2A cannot be displayed and the key lock,

communication lock and loader lock cannot be changed.

This status is called “password lock status”.

• The settings, which cannot be changed by the key lock, cannot be

displayed in the password lock mode.

• If the password lock cannot be unlocked, contact Yamatake or its

dealer. By returning the setting to the initial setting at Yamatake’s

factory, the password lock can be unlocked. In this case, note that the

data, which has been set by the customer, cannot be saved

(retained).

Item (Setting display/bank)

Display

Contents

Initial value

User level

Password display
(Setup setting/Lock bank)

0 to 15
5: Password 1A to 2B display

0

(The initial value
becomes “0” when
the power is turned
ON.)

Simple,
Standard,
High function

Password 1A
(Setup setting/Lock bank)

0000 to FFFF (Hexadecimal value)

0000

Simple,
Standard,
High function

Password 2A
(Setup setting/Lock bank)

0000 to FFFF (Hexadecimal value)

0000

Password 1B
(Setup setting/Lock bank)

0000 to FFFF (Hexadecimal value)

0000

Password 2B
(Setup setting/Lock bank)

0000 to FFFF (Hexadecimal value)

0000