Nor-Cal SDC15 Controller User Manual

Page 193

Advertising
background image

9-7

Chapter 9. LIST OF COMMUNICATION DATA

Bank

Item name

RAM address

EEPROM address

RAM

EEPROM

Decimal point

Remarks

Decimal Hexadecimal Decimal Hexadecimal Read Write Read Write information

SP

(Reserved for future extension.)

7001

1B59

23385

5B59

X

X

P

(Reserved for future extension.)

7002

1B5A

23386

5B5A

(Reserved for future extension.)

7003

1B5B

23387

5B5B

S

(Reserved for future extension.)

7004

1B5C

23388

5B5C

S

LSP1

7005

1B5D

23389

5B5D

P

Same as RAM address

13312 (decimal).

(Reserved for future extension.)

7006

1B5E

23390

5B5E

(Reserved for future extension.)

7007

1B5F

23391

5B5F

S

(Reserved for future extension.)

7008

1B60

23392

5B60

S

LSP2

7009

1B61

23393

5B61

P

Same as RAM address

13313 (decimal).

(Reserved for future extension.)

7010

1B62

23394

5B62

(Reserved for future extension.)

7011

1B63

23395

5B63

S

(Reserved for future extension.)

7012

1B64

23396

5B64

S

LSP3

7013

1B65

23397

5B65

P

Same as RAM address

13314 (decimal).

(Reserved for future extension.)

7014

1B66

23398

5B66

(Reserved for future extension.)

7015

1B67

23399

5B67

S

(Reserved for future extension.)

7016

1B68

23400

5B68

S

LSP4

7017

1B69

23401

5B69

P

Same as RAM address

13315 (decimal).

(Reserved for future extension.)

7018

1B6A

23402

5B6A

(Reserved for future extension.)

7019

1B6B

23403

5B6B

S

(Reserved for future extension.)

7020

1B6C

23404

5B6C

S

Event

Internal Event 1 main setting

7501

1D4D

23885

5D4D

S

Same as RAM address

13056 (decimal).

Internal Event 1 sub setting

7502

1D4E

23886

5D4E

S

Same as RAM address

13057 (decimal).

Internal Event 1 Hysteresis

7503

1D4F

23887

5D4F

S

Internal Event 1 ON delay time

7504

1D50

23888

5D50

S

Internal Event 1 OFF delay time

7505

1D51

23889

5D51

S

Internal Event 2 main setting

7506

1D52

23890

5D52

S

Same as RAM address

13058 (decimal).

Internal Event 2 sub setting

7507

1D53

23891

5D53

S

Same as RAM address

13059 (decimal).

Internal Event 2 Hysteresis

7508

1D54

23892

5D54

S

Internal Event 2 ON delay time

7509

1D55

23893

5D55

S

Internal Event 2 OFF delay time

7510

1D56

23894

5D56

S

Internal Event 3 main setting

7511

1D57

23895

5D57

S

Same as RAM address

13060 (decimal).

Internal Event 3 sub setting

7512

1D58

23896

5D58

S

Same as RAM address

13061 (decimal).

Internal Event 3 Hysteresis

7513

1D59

23897

5D59

S

Internal Event 3 ON delay time

7514

1D5A

23898

5D5A

S

Internal Event 3 OFF delay time

7515

1D5B

23899

5D5B

S

Internal Event 4 main setting

7516

1D5C

23900

5D5C

S

Same as RAM address

13062 (decimal).

Internal Event 4 sub setting

7517

1D5D

23901

5D5D

S

Same as RAM address

13063 (decimal).

Internal Event 4 Hysteresis

7518

1D5E

23902

5D5E

S

Internal Event 4 ON delay time

7519

1D5F

23903

5D5F

S

Internal Event 4 OFF delay time

7520

1D60

23904

5D60

S