Description of Commands

7-6

Continuous data read command (RS command)

This command reads data of continuous addresses by a single command.

Send message

This command enables the content of continuous data addresses starting with the

specified read start address to be read as a single message. The figure below

shows the structure of the application layer of the send message when the data is

read.

Response message

If the message is correctly received, a response message corresponding to the

command content is returned.

The figure below shows the structure of the application layer of the response

message when the data is read.

Maximum read data count per message

Up to 16 words for both RAM and EEPROM area

Chapter 7. CPL COMMUNICATIONS FUNCTIONS

(2)

(1)

(3)

(4)

Application layer

(1) Continuous read command
(2) Data delimiter
(3) Word address
(4) Read data count

R

0

S

,

1

5

1

W

,

1

(2)

0

• Normal termination (reading of single data item)

0

• Normal termination (reading of multiple data items)

0 0

• Abnormal termination

X X

The abnormal termination code is entered at XX.
For details of codes,
refer to

7-6, List of Termination Codes (on page 7-14).

(2)

(1)

(3)

(1) Termination code
(2) Data delimiter
(3) Data
(4) Data 2 to (n-1)
(5) Data (n)

,

(1) (2)

(3)

(4)

(5)

,

,

,

(2)

(2)

(1)