Chapter 9. list of communication data, List of communication data – Nor-Cal SDC15 Controller User Manual

Page 187

Advertising
background image

Chapter 9.

LIST OF COMMUNICATION DATA

9-1

List of communication data

The following shows the meanings of the symbols stated in the “RAM/EEPROM Read/Write”
columns:

No symbol: Possible.

:

Possible according to the conditions.

:

Possible, but data is invalid.

X:

Impossible.

Note: When reading the EEPROM address, data in the RAM is read in the same manner as

reading of the RAM address.

Decimal point information: No decimal point
1 to 3:

Decimal point position (The communication data becomes that the
original value is multiplied by 10, 100, or 1000.)

P:

Follows the PV input range.

S:

Follows various conditions.

RS/WS commands of CPL communication

Decimal data address with “W” attached next
to it is used.

RD/WD/RU/WU commands of CPL communication: Hexadecimal data address is used.
Commands of MODBUS communication:

Hexadecimal data address is used.

Bank

Item name

RAM address

EEPROM address

RAM

EEPROM

Decimal point

Remarks

Decimal Hexadecimal Decimal Hexadecimal Read Write Read Write information

Instrument

ROM ID

273

0111

16657

4111

X

X

"0" when using SDC15.

information

ROM Version 1

274

0112

16658

4112

X

X

2

ROM Version 2

275

0113

16659

4113

X

X

2

LOADER Information

276

0114

16660

4114

X

X

EST Information

277

0115

16661

4115

X

X

Manufacturing date code (year)

278

0116

16662

4116

X

X

Christian year - 200 Example:

Year of 2003 is expressed as "3"

Manufacturing date code (month, day)

279

0117

16663

4117

X

X

2

Month + (Day ÷ 100) Example:

Dec. 1st is expressed as "12.01".

Serial No.

280

0118

16664

4118

X

X

Lock

Key lock

5001

1389

21385

5389

Communication lock

5002

138A

21386

538A

X

X

When the communication lock

exists, the error response is sent.

Loader lock

5003

138B

21387

538B

X

X

Password display

5004

138C

21388

538C

X

Password 1A

X

X

X

X

Communication and loader cannot

read and write the password.

Password 2A

X

X

X

X

Same as above.

Password 1B

X

X

X

X

Same as above.

Password 2B

X

X

X

X

Same as above.

User

User Function 1

5101

13ED

21485

53ED

Function

User Function 2

5102

13EE

21486

53EE

User Function 3

5103

13EF

21487

53EF

User Function 4

5104

13F0

21488

53F0

User Function 5

5105

13F1

21489

53F1

User Function 6

5106

13F2

21490

53F2

User Function 7

5107

13F3

21491

53F3

User Function 8

5108

13F4

21492

53F4

Setup

PV input range type

5201

1451

21585

5451

Temperature unit

5202

1452

21586

5452

Cold junction compensation (T/C)

5203

1453

21587

5453

Decimal point position

5204

1454

21588

5454