1 config | amplifier – Comtech EF Data LPOD-R User Manual

Page 100

Advertising
background image

LPOD-R Outdoor Amplifier / Block Up Converter

MN-LPODR

Ethernet-based Remote Product Management

Revision 1

4–14

4.4.6 Config Pages

Use the Configuration pages to configure all operating parameters for the LPOD-R.

4.4.6.1 Config | Amplifier

Use this page to configure the communications, operations and alarms/faults handling for the

amplifier. Refresh the page to see the latest data.

Figure 4-4. Config | Amplifier Page

Amplifier

Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.

Fault Recovery – Use the drop-down list to select Automatic or Manual.

User Mute – Use the drop-down list to select Enabled or Disabled.

Click Change Configuration to save any changes.

Low Forward Power Threshold (dBm)

Set the threshold value, in dBm, for the low forward power alarm/fault.

When the forward power monitor is set to Alarm or Fault instead of the factory default of Mask,

and the forward power drops below the specified value, the alarm/fault occurs.

To disable the threshold, set this parameter to the default value of 00.00.

Click Change to save any changes.