LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–21

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Retrieve

Maintenance

Status (cont)

N/A

213 bytes

alphanumeric

Example: <1/RMS?’cr’

>0001/RMS=

LINEV=046.9

LINEA=000.3

LNBVT=XXXXX

P13VT=XXXXX

P10V1=010.5

A10V1=XXXXX

A10V2=XXXXX

P7V8T=XXXXX

P5V8T=006.1

P2V5T=XXXXX

P1V2T=001.3

N5V8T=-03.6

FAN1V=010.3

FAN1A=011.6

BUCVT=XXXXX

FWPWR=<24.0

REFVT=XXXXX

LNBCS=XXXXX

ATEMP=028.0

OTEMP=011.0

Note: LNBVT, FANR2, A10V2, BUCVT, REFVT, LNBCS, and OTEMP display when the appropriate options are installed;

Otherwise, the value fields shall be padded with X’s

Retrieve Next

5 unread

stored

Events

N/A

75 bytes

Query only.

Unit returns the oldest 5 Stored Events that have not yet been read over the remote control. Reply format: {CR}Sub-

body{CR}Sub-body{CR}Sub-body{CR} Sub-body{CR}Sub-body, where Sub-body= ABCCddmmyyhhmmss:

A = Fault/clear indicator:

F=Fault

C=Clear

I=Info

B = Fault type:

1=Unit

2=RF

3=Log

CC = Fault Code numbers (as in RAS?) or Info Code:

0=Power Off

1=Power On

2=Log Cleared

3=Global Config Change

4=Redundancy Config Change

RNE=

RNE?

RNE={CR}ABC

Cddmmyyhhmm

ss{CR}ABCCdd

mmyyhhmmss{

CR}ABCCddmm

yyhhmmss{CR}

ABCCddmmyyh

hmmss{CR}ABC

Cddmmyyhhm

mss

(See Description

of Arguments for

details)