Comtech EF Data LPOD-R User Manual

Page 129

Advertising
background image

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–19

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Retrieve

Alarm Status

(cont)

SHTDN=OK’cr’ Over-temp shutdown

IICST=OK’cr’ I2C bus status

FWPWR=MS’cr’ Forward power in dBm

CHKSM=OK’cr’ Flash checksum

FPGAD=NA’cr’ FPGA done status

BUCLD=OK’cr’ BUC lock detect

REFLD=NA’cr’ Reference lock detect

LNBCS=NA’cr’ LNB current status

SWITC=NA’cr’ Waveguide switch position status

RDLNK=NA’cr’ Redundant link status

TRMST=YS’cr’ Terminal Status

UNAFW=OK’cr’’lf’ Unaccepted Firmware

Note: Field values display when the appropriate model/options are selected/installed. Otherwise, unused fields display NA.

Reboot

RBT=

1 byte

Command only.

Performs a Soft Reboot of the unit, where:

1 = Reboot System

Example: <1/RBT=’cr'

RBT=

RBT?

RBT*

N/A

RBT=x

(See Description

of Arguments for

details)

Retrieve

Configuration

Status

N/A

45 bytes

Query only.

Returns the configuration status of the unit, where:

ATT= attenuation, in dB

AMP= RF power amplifier state:

0=OFF

1=ON

MUT=RF mute state:

0=unmuted

1=muted

RED=Online status for redundancy

ESW=Redundancy state and mode state:

0=OFF

1=ON Tx only

2=ON Tx & Rx

AOF=Attenuator Offset, in dB

AFR= auto fault recovery

0 = manual

1 = auto

XRF = External reference status:

N/A = no external reference

05M = 5 MHz

10M = 10 MHz

RCS=

RCS?

RCS=x….x

(See Description

of Arguments for

details)

Advertising