Comtech EF Data LPOD-R User Manual

Page 119

Advertising
background image

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–9

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Auto Fault

Recovery

AFR=

1 byte

Command or Query.

Enables or disables Auto Fault Recovery. The LPOD output is automatically muted if any of the following fault conditions

occur: BUC lock detect fault, LNB current fault (see Note), or LNB voltage fault (see Note). If enabled, auto fault recovery

causes the output to return to its pre-fault mute condition if all faults are cleared. If disabled, the output remains muted even

if all faults are cleared. Command/query is in the form x, where:

0 = Disable

1 = Enable

Default Value: 1

Example: <1/AFR=1’cr’

>0001/AFR=’cr’’lf’

Note: This fault can be user-defined as fault, alarm, or masked (see MSK command for more info).

AFR=

AFR?

AFR*

AFR?

AFR=x

(Same format as

command

arguments)

Attenuation

ATT=

5 bytes

Command or Query.

Sets or returns the attenuation level, in dB, in the form xx.xx, where:

xx.xx = 00.00 to 20.00 in 0.25 dB steps.

Default Value: 10.00

Example: <1/ATT=12.25’cr’

>0001/ATT=’cr’’lf’

ATT=

ATT?

ATT*

ATT?

ATT=xx.xx

(Same format as

command

arguments)

Clear All

Stored

Alarms

E

CAA=

None

Command only.

Instructs the unit to clear all Stored Alarms. This command takes no arguments.

Example: <1/CAA=’cr’

>0001/CAA=’cr’’lf’

CAA=

CAA*

N/A

N/A

Clear All

Stored

Events

CAE=

None

Command only.

Instructs the BUC to clear all Stored Events. This command takes no arguments.

Example: <1/CAE=’cr’

>0001/CAE=’cr’’lf’

CAE=

CAE*

N/A

N/A