LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–10

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Concise

Alarm Status

Concise

Alarm Status

(cont)

N/A

44 bytes

Query only.

Returns the Alarm status of the unit. This is the concise version of the RAS command, response is semicolon delimited, in

the form a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;z;aa’cr’’lf’ where:

a thru z = 0, 1, 2, 3, 4, or 5

0 = FT

1 = OK

2 = AL

3 = NO

4 = YS

5 = MS

a = LINEV

b = LINEA

c = LNB Power Supply (N/A)

d = +13.5V Power Supply (N/A)

e = +10V Power Supply

f = +10V1 Amplifier Power Supply

g = +10V2 Amplifier Power Supply (N/A)

h = +7.8V Power Supply (N/A)

i = +5.8V Power Supply

j= +2.5V Power Supply (N/A)

k = +1.2V Power Supply

l = -5V Power Supply

m = Fan1V

n = Fan1A

o = Heatsink Temp

p = Overtemp Shutdown

q = llC Status

r = Forward Power Alarm

s = Flash Checksum

t = FPGA Done (N/A)

u = BUC Lock Detect

v = External Ref Lock Detect (N/A)

w = LNB Current (N/A)

x = Redundant Switch Condition (N/A)

y = Redundant Link Status (N/A)

z = Terminal Status Change

aa = Unaccepted Firmware

Note: Field values appear only if the appropriate model/options are selected/installed. Otherwise, the unused fields display

NA.

CAS=

CAS?

CAS=x….x

(See Description

of Arguments for

details)