Comtech EF Data LPOD-R User Manual

Page 130

Advertising
background image

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–20

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Retrieve

Configuration

Status (cont)

Example:

<1/RCS?’cr’

>0001/RCS=’cr’

ATT=12.75’cr’

AMP=1’cr’

MUT=1’cr’

ONL=1’cr’

ESW=1’cr’

AOF=00.00’cr’

AFR=1’cr’

XRF=N/A’cr’’lf’ (see Note 2)

Notes:

1) Unused fields shall be padded with X’s.

2) XRF is always N/A when the internal reference oscillator option is not installed.

Retrieve

Equipment

Type

E

N/A

22 bytes

Query only.

Returns a string indicating the Model Number and the version of the installed M&C firmware.

Example: <1/RET?’cr’

>0001/RET=LPOD-R VER: 1.1.1’cr’’lf’

RET=

RET?

RET=x….x

(See Description

of Arguments for

details)

Retrieve

Maintenance

Status

N/A

213 bytes

alphanumeric

Query only.

Returns the maintenance status of the unit, where:

LINEV = LINE voltage

LINEA = LINE amperage

LNBVT = +13/18V LNB power supply (see Note)

P13VT = +13.5V power supply

P10V1 = +10V1 power supply

A10V1 = 10V1 on RF Module

A10V2 = 10V2 on RF Module (see Note)

P7V8T = +7.8V power supply

P5V8T = +5.8V power supply

P2V5T = +2.5V power supply

P1V2T = +1.2V power supply

N5V8T = -5.8V power supply

FAN1V = Fan 1 voltage

FAN1A = Fan 1 current

BUCVT = BUC tuning voltage (see Note)

FWPWR = Forward power in dBm

REFVT = Reference osc. tuning voltage (see Note)

LNBCS = LNB current supply in mA (see Note)

ATEMP = Heatsink temperature in Celsius

OTEMP = Outdoor temperature in Celsius (see Note)

RMS=

RMS?

RMS=x….x

(See Description

of Arguments for

details)