Electrical Safety Notice

CAUTION – Neutral Fusing – Double pole/neutral fusing is used on the prime power
supply input.

This equipment has been designed to minimize exposure of personnel to hazards. For further

information, contact Comtech EF Data, Customer Support Department. The operators and

technicians must:

• Know how to work around, with, and on high voltage equipment.

• Exercise every precaution to ensure personnel safety.

• Exercise extreme care when working near high voltages.

• Be familiar with the warnings presented in this manual.

Installation Guidelines Regarding Power Line Quality

Comtech EF Data has become familiar with the varying quality of the AC power grid
around the world. Observing the following installation guidelines should help ensure a
reliable installation.

Surge suppression: High voltage surges can cause failure of the power supply. These surges

are typically caused by circuit switching on the main AC power grid, erratic generator

operation, and also by lightning strikes. While the LPOD-R does have built in surge

suppression, if the unit is to be installed in a location with questionable power grid quality,

Comtech EF Data recommends installation of additional power conditioning/surge

suppression at the power junction box.

Grounding: The LPOD-R provides a grounding terminal. This is provided to allow you to

ground the LPOD-R to the antenna’s grounding network. All components installed at the

antenna should be grounded to a common grounding point at the antenna.

Electrical welding: If welding needs to take place at the antenna, disconnect all cables from

the LPOD-R except for the ground wire. Cap all RF connections with terminations. This will

prevent damage to the input/output circuitry of the LPOD-R.

Lightning: Lightning strikes on or around the antenna will generate extremely high voltages

on all cables connected to the LPOD-R. Depending on the severity of the strike, the LPOD-R’s

internal surge protection combined with the recommended external suppression may

protect the LPOD-R’s power supply. However, if the installation will be in an area with a high

probability of lightning strikes, Comtech EF Data recommends the installation of surge

suppression on the RF and IF cables. One source of these suppressors is PolyPhaser

(

2H

www.polyphaser.com).