Comtech EF Data LPOD-R User Manual

Page 133

Advertising
background image

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–23

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Serial

Number

E

N/A

9 bytes

Query only.

Returns the unit’s 9 digit serial number in the form xxxxxxxxx.

Example: <1/RSN?’cr’

>0001/RSN=072282040’cr’’lf’

RSN=

RSN?

RSN=xxxxxxxxx

(See Description

of Arguments for

details)

Retrieve

Utility Status

N/A

15 bytes

Query only.

Returns the utility status of the unit, response is comma delimited. Exists only for backward compatibility.

Example:

<1/RUS?’cr’

>0001/RUS=’cr’’lf’

ADR=XXXX

BDR=XXXXX

REF=XXX’cr’’lf’

RUS=

RUS?

RUS=x….x

(See Description

of Arguments for

details)

Set FSK

Address

SFA=

2 bytes,

numeric

Command or Query.

Sets or returns the FSK Address in the form xx, where:

xx = 01 to 15

Default Value: 01

Example: <1/SFA=01’cr’

>0001/SFA=’cr’’lf’

SFA=

SFA?

SFA*

SFA?

SFA=xx

(See Description

of Arguments for

details)

Serial

Number

N/A

9 bytes

Query only.

Returns the unit’s nine-digit serial number in the form xxxxxxxxx.

Example: <1/SNO?’cr’

>0001/SNO=072282040’cr’’lf’

Note: This query is functionally identical to RSN.

SNO=

SNO?

SNO=xxxxxxxxx

(See Description

of Arguments for

details)

Set Statistics

Interval

SSI=

2 bytes

Command or Query.

Sets or returns the interval at which statistics are logged in minutes, in the form xx, where:

xx =. 01 (min) to 99 (max)

Default Value: 90

Example: <1/SSI=90’cr’

>0001/SSI=’cr’’lf’

SSI=

SSI?

SSI?

SSI=xx

(Same format as

command

arguments)

Software

Revision

N/A

34-37 bytes

Query only.

Returns the firmwares installed in the Active and Pending images:

Example: <1/SWR?’cr’

>0001/SWR=FW-0020765;1.1.1mx;03/19/14 PendingImage INVALID

SWR=

SWR?

SWR=x.y.zz

x.y.zz

(See Description

of Arguments for

details)

Advertising