LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Introduction

Revision 1

1–8

1.5.2

Environmental

Temperature

Operating

Standard -40º to 122ºF (-40º to 55ºC)

Optional

-58º to 131ºF (-50º to 55ºC) or -40º to 140ºF (-40º to
60ºC)

Storage

-67º to 167ºF (-55º to 75ºC)

Humidity

100% condensing rain 2” per hour

Altitude

10,000 AMSL

Shock

Normal commercial shipping and handling

1.5.3

Physical

Weight

PS .5

5 lbs. (2.3 kg) Nominal

PS 1

17 lbs. (9.1 kg) Nominal

PS1.5

Dimensions
(excluding connectors)
See Section 1.6.

PS .5

7.21 x 4.65 x 3.34 in. (183.1 x 118.1 x 84.8 mm)

PS 1

12.60 x 6.31 x 6.05 in. (320.0 x 160.3 x 153.7 mm)

PS 1.5

12.78 x 6.14 x 6.47 in. (324.6 x 155.9 x 164.3 mm)

Connectors

IF/RF Input

Type ‘N’ Female

RF Output

PS .5

C-Band: CPR137G
Ku-Band: WR75G

PS 1

C-Band: Type ‘N’ Female (optional CPR137G)
X-Band: CPR112G
Ku-Band: WR75G

PS 1.5

C-Band: CPR137G
X-Band: CPR112G
Ku-Band: WR75G

M&C
(Ethernet)

PS .5

Weatherized RJ-45

PS 1

Optional 19-pin MS style (single integrated cable
assembly available, dependent upon configuration)

PS 1.5

1.6

Dimensional Envelopes

Typical for all figures in each subsection, all dimensions are in inches. Bracketed dimensions,

where shown, are in metric units (mm).

Advertising