5.2.1 Removal

STEP 1

c

WARNING: Hazardous Voltage! Turn off all power sources to actuator before removing
control module assembly. Power sources may include main power or control power.

a

CAUTION: Potential to cause electrostatic damage to electronic components. Before
handling electronic components, ensure that you are discharged of static electricity by
briefly touching a grounded metal object.

If the I/O option board is installed, disconnect
wire harness plug P3 and P4.

1

P3

P4

STEP 2

If DDC board is installed, disconnect wire
harness plug P2.

2

P2

STEP 3

Disconnect wire harness plug P1 and P4 from
the main processor board.

3

P1

P4