1 removal – Flowserve MX Limitorque User Manual

Page 149

Advertising
background image

141

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

5.17 Motor Lead Harness (MX-85, -140, and -150)

Figure 5.20 – Motor Lead Assembly








5
5

5

5I

5I

5I

5I









5

5

5





5P.PUPS

1JO ".11MVH

5P$POUBDUPS

1JO ".11MVH

5P$POUBDUPS

1JO ".1$BQ

4FBM

5P.BJO1SPDFTTPS#PBSE

.PMFY1JO 1

.PMFY3FDFQUBDMF

5.17.1 Removal

NOTE: Before removal you must:
1. Remove the motor (subassembly #4). (See Section 4.1.1)

2. Remove the CP (subassembly #7). (See Section 5.1)

3. Remove the control module (subassembly #15). (See Section 5.6.1)

4. Remove the contractor assembly (subassembly #8). (See Section 5.10.1)

STEP 1

If the worm shaft assembly (subassembly #3)
is still mounted in the unit, remove the four
screws (#3-9) and rotate the cap (CCW) to
rotate the cap tab away from the motor lead
seal.

1

Cap

Tab

Motor

Lead

Seal

Advertising
This manual is related to the following products: