2 remounting – Flowserve MX Limitorque User Manual

Page 81

Advertising
background image

73

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

STEP 3 (VIEWED FROM TOP-MOUNTED HANDWHEEL SIDE OF ACTUATOR)

a

CAUTION: (MX-20 and -40 only) When
removing or remounting drive sleeve
assembly, take precaution not to bump
drive sleeve assembly against encoder
drive cartridge (subassembly #14).

TIP: Worm gear flat turned parallel with
encoder drive cartridge (subassembly #14) to
permit drive sleeve assembly removal.

3

Worm

Gear

Flat

Encoder

Drive

Cartridge

(14)

4.12.2 Remounting

STEP 4

NOTE: Before remounting drive sleeve assembly, ensure that bearing (#3-5) is in place in the
actuator housing. (Refer to motor subassembly #3 Step 1 for details.)

Lightly lubricate the top and bottom of the drive
sleeve assembly as shown.

Lubricate areas between
lines

4

STEP 5

a

CAUTION: (MX-20 and -40 only) When removing or remounting drive sleeve assembly,
take precaution not to bump drive sleeve assembly against encoder drive cartridge
(subassembly #14).

Push the drive sleeve assembly into the base
of the actuator housing until the lower bearing
(#2-4) is fully engaged in the housing up to
the shoulder. If the bearing is a tight fit, gently
tap the bottom of the drive sleeve (#2-1) with a
mallet to properly seat.

MX-85, -140, and -150: See Section 4.12.4
for optional remounting of drive sleeve and
baseplate.

5

2-1

2-4