115

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

After enabling the Modutronic option, if digital inputs are used for control, remote control may be set

to user inputs.

For adding the APT, ATT, and R options, the analog output board(s) and/or the digital output board(s)

will be required. When these board(s) are installed into the actuator, it will already have the option(s)
enabled. The unit will recognize the board and turn on the required software menu feature. Please
refer to the IOM manual, LMENIM2306, supplied with your actuator for the Menu sequence. The user
will need to enable the menu options. Please contact your assigned Service Coordinators for purchase
of these desired options at (434) 528-4400.

For adding the DDC, FF, DN or PROFIBUS option, the DDC, FF, DeviceNet or PB option board is

required. When these boards are received and installed into the actuator, it will recognize the board
and turn on the required software menu feature. Please refer to the IOM manual, LMENIM2306,
supplied with your actuator for the Menu sequence. The user will need to enable the menu options.
Please contact your assigned Service Coordinators for purchase of the network options at (434)
528-4400.

5.7 Restoring Power to Actuator

with New Control Module

Figure 5.11 – Restoring Power to Actuator with New Control Module

YES

NO

NO

YES

NO

YES

YES

YES

NO

NO

YES

NO

UNIT SIZE

MX-05-OK?

VOLTAGE

460 VOLT-OK?

Hz

60 Hz-OK?

ACTUATOR RP M

12/18-OK?

S/N

0------OK?

COLD (-50°C) UNIT

YES/NO -OK?

INITIALIZE?

Answer “

NO ” until the

correct unit size is

displayed. Refer to

nameplate.

Answer “

NO ” until

the correct voltage

is displayed. Refer

to nameplate.

Answer “

NO ” until

the correct frequency

is displayed. Refer to

nameplate.

Answer “

NO ” until

the correct rpm

is displayed. Refer

to nameplate.

Answer “

NO ” until the

value is displayed and

then “

YES ” to enter .

Refer to namplate for

S/N.

Answer “

NO” to

select normal

temperature

parameters,

-22°F to +158°F

(-30°C to +70°C).

Answer “

YES” to select arctic

temperature parameters,

-58°F to +140°F (-50°C to

+60°C).

Please refer to Limitorque

MX Customer Connection(s) Diagram

(#L2180) reverse side (located on the

inside of the terminal compartment

cover) for customer default

configuration.

Answer

NO” to

change.

Answer “

YES

to save settings.

NO

YES

5.8 Terminal Block (prior to March 2007)

Table 5.5 – Terminal Block Parts List

Part Number

Description

Qty.

1-20

O-ring

1

1-21

Retaining ring

1

1-43

Pan head (M3x4) plastic screw

2

8-15

Terminal block

1

8-16

Self-lock combo head screw (M3x5)

48

8-17

Self-lock combo head screw (M5x8)

3

8-18

Cover plate

1

8-19

Pan head self-tapping screw

2

8-20

Control wiring harness

1