2 remounting – Flowserve MX Limitorque User Manual

Page 77

Advertising
background image

69

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

4.11.2 Remounting

STEP 2

a

CAUTION: The drive sleeve surface serves as an oil-sealing surface. Use caution not to
scratch the drive sleeve while completing removal and remounting.

Lightly lubricate the top and bottom of the drive
sleeve assembly as shown.

Lubricate

Lubricate

2

STEP 3

Insert the drive sleeve assembly into the
actuator housing base until the lower bearing
(#2-4) is fully engaged in the housing (seated
on actuator shoulder). If the bearing is a tight
fit, gently tap the bottom of drive sleeve (#2-1)
with a mallet to properly seat.

3

2-4

STEP 4

Remount all removed subassemblies according to their remounting instructions in the following
order:

1. Base plate (subassembly #11). (See Section 4.9.2.)

2. Worm shaft (subassembly #3). (See Section 4.10.2.)

3. Motor (subassembly #4). (See Section 4.1.2.)

4. Thrust base (subassembly #10) - if fitted. (See Section 4.7.2.)

Advertising