Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

134

5.14.1 Removal

NOTE: Before removal you must:

1. Drain oil.

2. Remove the CP cover (subassembly #7). (See Section 5.1.)

3. Remove the control module (subassembly #8). (See Section 5.2.1.)

4. Remove the encoder (subassembly #6). (See Section 5.13.1.)

STEP 1

c

WARNING: Hazardous Voltage! Turn off all power sources to actuator before removing
encoder drive cartridge. Power sources may include main power or control power.

Remove the M4 screw (#14-8) using a 3 mm
hex key.

1

14-8

STEP 2

Withdraw the complete encoder drive cartridge
from the actuator housing.