1 removal, 2 remounting – Flowserve MX Limitorque User Manual

Page 41

Advertising
background image

33

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

4.3.1 Removal

STEP 1

c

WARNING: Potential to operate while dangerous mechanical parts are exposed during
subassembly removal. To prevent injury, turn off all power sources to actuator before
removing top-mounted handwheel assembly. Power sources may include main power
or control power.

Using a 6 mm (MX-05 and -10) hex key or
8 mm (MX-20 and -40) hex key, remove the
four screws (#1-11) that secure the handwheel
(#1-8) to the handwheel adapter assembly
(#1-1).

1

11-1

1-8

STEP 2

Lift the handwheel (#1-8) off the handwheel
adapter (#1-1).

2

4.3.2 Remounting

STEP 3

Install handwheel (#1-8) onto handwheel
adapter assembly (#1-1).

3

1-8

1-1

Advertising