147

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

STEP 9

Mount new power assembly (1-19) on top of the three standoffs (1-55) using the existing three M4
power assembly screws (1-45).

a

CAUTION: Assure the voltage jumper on the power board is located in the proper location
per the nameplate and motor voltage! See Figure 5.8 for location of jumper.

STEP 10

Route the two-pin AMP plugs (L1 power connector) over the bottom plate of the control module
and connect to the ceramic fuse block plug.

NOTE: 1-53 SSMR protection fuse Limitorque part number 102476, Bussmann part number
FWP-30A14F.

STEP 11

Referring to Section 5.2.2, connect all plugs.

STEP 12

Mount the CP cover assembly per Section 5.1. Applicable wiring diagrams: 1792, 1793, 1794,
1795, 1796, and 1797.

5.19 Mounting of SSMR (Solid State Motor

Reverser) in units shipped after February 2008

Table 5.19 - SSMR Parts List

Part Number

Description

Qty.

1-18

Controls cover assembly

1

7-27

Socket head cap screws

4

1-52

Solid state reverser power assembly

1

1-55

Standoff

3