STEP 2

If actuator is already in service, disconnect
incoming power leads L1, L2, and L3 (and
control wiring from the terminal block if
terminal block replacement is required).

2

STEP 3

Using a flat head screwdriver, insert the
screwdriver blade underneath the edge of the
snap ring (#1-21) and work the blade around
the back of the snap ring to remove it from the
groove, thus allowing terminal block removal.

3

1-21

STEP 4

Remove terminal block assembly.

4

Terminal

Block

Assembly

STEP 5

Disconnect leads L1, L2, and L3 from back of
terminal block.

5