85

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

STEP 6

NOTE: Lightly lubricate quad rings/O-rings before remounting subassemblies.

Fit the handwheel adapter assembly (#12) into
the top of the actuator housing. Slowly rotate
the assembly as it approaches its lower posi-
tion in the actuator; this will allow the quad ring
(#12-3) to ease over the end of the drive sleeve
avoiding damage to the quad ring.

6

Quad Ring (12-3)

Located Inside

Handwheel Adapter

12

STEP 7 (MX-20 AND -40 ONLY)

Place the O-ring (#12-4) around handwheel
adapter, pressing the O-ring into the slot
between the handwheel adapter assembly (#12)
and the actuator housing (approximately every
15° to 30°) until the O-ring seats into slot.

7

12-4