Flowserve MX Limitorque User Manual

Page 121

Advertising
background image

113

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

Figure 5.10 – Option Board Assembly

DEVICENET OPTION BOARD GROUNDING

WIRE MOUNTED UNDER TOP OPTION

BOARD SCREW HEAD ABOVE THE SHEILD.

MOUNTING SCREWS

SEE TABLE FOR PART

NUMBER AND SIZE

TOP SHIELD REQUIRED IF

ONE OR MORE OPTION

BOARDS ARE PROVIDED.

THIS SHIELD WITH TABS BENT IS ONLY REQUIRED WHEN MOUNTING

DIGITAL OUTPUT BOARD BETWEEN ONE OPTION BOARD AND THE MAIN

BOARD OR BETWEEN 2 OPTION BOARDS.

DIGITAL OUTPUT BOARD SHOWN MOUNTING IN BETWEEN OTHER

OPTION BOARDS, NOTE THAT SHIELD IS REQUIRED ON TOP OF

THIS BOARD IF MOUNTED AS TOP OPTION BOARD OR MOUNTED

IN BETWEEN OTHER OPTION BOARDS.

GROUND WIRE FOR DEVICENET

BOARD MUST BE MOUNTED UNDER

TOP OPTION BOARD ABOVE THE

SHIELD AND CONTACTING THE

SCREW. MOUNTING SCREW AS

SHOWN IN ‘ASSEMBLED COVER VIEW’

ASSEMBLED COVER VIEW

MAIN BOARD

CONTROLS COVER ASSEMBLY

OPTION BOARD 1

OPTION BOARD 2

BEND TAB UP 2 PLACES

OPTION BOARD 3

OPTION BOARD 4

Table 5.5 - Screw Part Numbers

BOARD DESCRIPTION

SCREW PART NUMBER

DESCRIPTION

QTY.

MAIN WITH

NO OPTION BOARDS

64-818-0001-35

M4X8

4

MAIN WITH

1 OPTION BOARD

64-818-0001-32

M4X25

4

MAIN WITH

2 OPTION BOARDS

64-818-0001-36

M4X40

4

MAIN WITH

3 OPTION BOARDS

64-818-0004-3

M4X55

4

MAIN WITH

4 OPTION BOARDS

64-818-0005-3

M4X70

4

a

CAUTION: Potential to pinch cables. When remounting ACP cover, take special care not to pinch
ribbon cables.

Dress the cables being careful to position wires so that they pass perpendicularly over the housing
flange.

NOTE: The face of the ACP may be installed in any one of four 90° incremental positions. When
changing ACP position, avoid over-twisting the ribbon cable(s).

Rotate the ACP until the display orientation of the front face is correct for normal viewing, and then slide
the ACP assembly into the actuator housing.

Advertising