SiteOmat Setup and Maintenance Manual – MDE 4817G
Table 6-7. Setup Comms Sections
Section
Description
General
Provides communication attributes of the Controller.
FCC IP:
Identifies the IP address of the Controller in the network for view
only. The connection is identified at the FCC Port box (LAN1 or LAN2)
and the Control Port box.
Maintenance time
: Sets the time of the day, Hours and Minutes after
midnight, at which the SiteOmat performs clean up operations of the
database and other activities. The duration of the maintenance procedure
depends on the workload of the OrCU, which is the number of transactions
not passed to Head Office. This process may take a few minutes, during
which the system may experience a delay in authorizing and other
operations. Therefore, it is highly recommended to select a time where no
activity or minor activity is expected in the station. Default procedure time
is five minutes after midnight.
Maximum transactions
: Sets the Controller's transactions capacity
Delete transactions older than
: Enables overriding of transactions in
FIFO method if transactions number is over the maximum set
Connected to HO
: Deletes transactions only after data was transferred to
HO (in cases where overriding is selected)
Keep data for
: Sets the time limit for storing the transactions. This field
enables users to delay the clean up, as it may be required for obtaining
local reports (request available data from the last days)
Communication
This section is for information only and cannot be set.
Head Office Trigger
This section is set in cases where the Head Office is implemented. The
Trigger requires a message from the OrCU, through Web Services, to
activate the Head Office and update the OrCU. The feature is disabled by
default. As these are very specific settings, additional information is
provided for developers of Head Office on demand.
Remote
Authorization
This section is set in cases where the Head Office application provides
Web Services in a predefined format for authentication. Specific settings
are provided for these applications only.
Log Server
Defines a remote server that captures log information provided by the
OrCU. When the IP and port of the server are defined, the OrCU
automatically starts sending UDP log messages to the specified port. OrCU
does not check if the message was delivered.
A Log Server application is provided by Gasboy. It is a Windows
application that listens in on the UDP port and writes the log messages to