85
SiteOmat Setup and Maintenance Manual – MDE 4817G
4-5. MAIN SETUP SCREEN – BASIC MODE
The next screen is the main setup screen with the dispensers (pump heads), located on the left side
of the grid, and the nozzles (Hoses), located on the right side of the grid (see Figure 4-24).
Figure 4-24. Main Setup Screen – Basic Mode
For stations equipped with one-grade pumps only, set the Cut off Delay (see Step 6 below) and
verify that the Factor (for mechanical pumps only), the Tank to which the pump is connected and
the F.P. Plus Channel and F.P. Plus Satellite Channel (if any) which should be already set after
running the Wizard (refer to paragraph 4-4.7) are correct. Change the settings if needed using the
corresponding drop-down lists.
In order to complete the setup process, click on the Reload button.
For stations equipped with multi-grade pumps, proceed as follows:
1. Click on the ellipsis (…) button to open the Setup Pump Settings dialog box (see
Figure 4-25)