MAINTENANCE

HySpeed HT2000LHF

Instruction Manual

5-13

6

To determine if there is a problem with the chopper modules or with control board PCB2 or analog board PCB3,

proceed as follows:

• Ensure that the high frequency is still disabled (see step 1).

• Disconnect PL3.1 from REC1 on PCB3.

• Place voltmeter across the output of the chopper and press the START command.

• If the voltmeter reads +280 VDC, then replace either control board PCB2 or analog board PCB3.

• If the voltmeter reads 0 volts, then replace the corresponding chopper module CH1 or CH2.

Figure 5-4

Chopper Module – Front View

Bridge (+)

- TORCH

+ WORK

Bridge (–)

LED3

LED1

JP9

JP6