Gas console connections – Hypertherm HT200LHF-200 Volt HySpeed User Manual

Page 47

Advertising
background image

Gas Console Connections

See page 3-9 for gas console connection to power supply.

Argon-Hydrogen Cable – Power Supply to Argon-Hydrogen Manifold

See the appendix section for Argon-Hydrogen installation and operation.

INSTALLATION

3-14

HySpeed HT2000LHF

Instruction Manual

6

11X1

Hold Cable – Power Supply 1 to Power Supply 2

Color

TB3

Signal

Black

13

Hold Signal

Red

14

Hold Common

Shield

15

Hold Shield

Part No.

Length

023340

15 ft (4.6 m)

023341

25 ft (7.6 m)

023342

50 ft (15 m)

023343

100 ft (30.5)

023344

150 ft (46 m)

12

13

Initial Height Sensing Cable – Power Supply to Initial Height Sensing Console

See the appendix section for Initial Height Sensing connections.

14

Shield Gas Hose – Gas Console to Power Supply

Note: Turn counterclockwise to tighten

15

15

12

Part No.

Length

024348

5 ft (1.5 m)

024313

10 ft (3 m)

024302

15 ft (4.6 m)

024349

20 ft (6.1 m)

024303

25 ft (7.6 m)

024350

30 ft (9.1 m)

024351

35 ft (10.7 m)

024352

40 ft (12.2 m)

024353

45 ft (13.7 m)

024304

50 ft (15 m)

024305

75 ft (23 m)

024306

100 ft (30.5 m)

024312

150 ft (46 m)

Timer/Counter Cable – Power Supply to Timer/Counter

11

11

Part No.

Length

023687

10 ft (3 m)

023692

25 ft (7.6 m)

023758

38 ft (11.6 m)

023693

50 ft (15 m)

123046

60 ft (18.3 m)

023694

75 ft (23 m)

123079

85 ft (25.9 m)

023695

100 ft (30.5)

023993

115 ft (35.1 m)

123189

120 ft (36.6 m)

023696

150 ft (46 m)

023954

200 ft (62 m)

11x1

TB3

Color

Signal

1

2

White

Starts and Arc time (CON1 Closed)

2

1

Black

Starts and Arc time (CON1 Closed)

3

3

Drain

Drain

15

5

Red

Error Counter (Ramp Down Error)

16

4

Black

Error Counter (Ramp Down Error)

12

6

Drain

Drain

Advertising