4-1

6

Front Panel Controls and Indicators

Status Indicators Before Startup

When power is applied from the line disconnect switch and before the POWER ON (I) button is pushed, the coolant

flow LED will always be illuminated. Once the POWER ON button is pushed and held for a few seconds, this LED

will extinguish if the system is in proper working condition.

Other fault conditions may also be indicated when the line power is switched on. Be sure to press and hold the

power supply POWER ON (I) button (in some cases up to 1 minute) to extinguish all status indicators. If any LEDs

remain illuminated, shut down the system and correct the problem. See

Status LED Troubleshooting

in

Section 5

,

if necessary.

Figure 4-1

Power Supply Front Panel Controls and Indicators

Section 4

OPERATION

ON (I)

Activates the power

supply and its control

circuits. Indicator

illuminates when power

up is complete and

status indicators are

satisfied.

OFF (O)

Shuts the power

supply down.

DC ON

Illuminates when main

contactor closes,

indicating DC power is

being supplied to the

torch.

INTERLOCK

LED

Spare. This LED is

always extinguished.

TRANSFORMER

LED

When illuminated, indicates that

either the power supply main

transformer or one of the choppers is

operating above the proper

temperature range.

COOLANT LEVEL

LED

When illuminated, indicates that

the coolant level is inadequate.

SHIELD GAS/CAP

LED

When illuminated, indicates that either the shield

gas pressure is inadequate, or that the retaining

cap is installed improperly on the torch.

PLASMA GAS

LED

When illuminated,

indicates that the

plasma gas pressure is

inadequate.

COOLANT TEMP

LED

When illuminated, indicates that

the torch coolant temperature is

too hot.

COOLANT FLOW

LED

When illuminated, indicates that the

coolant flow from the torch is

inadequate.