APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING

HySpeed HT2000LHF

Instruction Manual

a-7

6

After Cutting with Argon-Hydrogen

1. Turn off the power supply, and disconnect the power.

2. Turn MV1 to the closed position.

3. Disconnect the 14X1 argon-hydrogen cable from the

plasma system. See page a-2.

4. Remove the argon-hydrogen plasma gas torch lead from

the torch. See Figure a-4.

5. Remove the 015049 connector and connect the plasma

hose from the torch to SV5. See Figures a-3 and a-4

.

6. Remove the nitrogen supply hose from the shield supply

connection of the gas console.

7. Connect the nitrogen supply hose to the N

2

connection of

the gas console. See Figure a-6.

8. Connect the shield gas supply hose to the shield supply

connection of the gas console. See

Gas Console

Connections

in Section 3.

9. Reconnect the 4X1 end of the valve cluster cable to the

power supply off valve cable. See Figures a-4, 3-5 and

page 3-10.

MV1

Figure a-6

Nitrogen Supply to N

2

Input of Gas Console

Ni

trogen

2WRENCHES